Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 20.05.2026. Verfasst von Vicente Jesús León-Muñoz und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery and Traumatology, Hospital General Universitario Reina Sofía, Murcia, Spain. Die Arbeit nennt 52 Literaturangaben. Gefördert von: None.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The coronal plane alignment of the knee (CPAK) classification is based on fixed cut‐off values derived from the mechanical lateral distal femoral angle (LDFA) and the medial proximal tibial angle (MPTA). The present study evaluated the sensitivity of the CPAK classification to clinically plausible measurement error and examined its impact on population‐level category distributions.

Methods

A deterministic sensitivity analysis was conducted using four data sets: osteoarthritic knees (population A), the original CPAK healthy cohort (population B), and Turkish (population C) and Korean (population D) cohorts. CPAK distributions derived from original measurements were compared with those obtained after introducing fixed systematic measurement errors of 0.41° for LDFA and 0.71° for MPTA. Furthermore, a structured perturbation analysis was conducted by systematically varying the error magnitude from −4° to 4° to evaluate classification performance across a broader error spectrum.

Results

Clinically plausible measurement error resulted in substantial changes in CPAK distributions across all populations. The mean absolute percentage changes were 36.2% for population A, 43.95% for population B, 89.94% for population C and 45.18% for population D. The most pronounced effects were observed at classification thresholds, where minor angular deviations frequently led to category reassignment.

Conclusions

The CPAK classification system demonstrates marked sensitivity to minor errors in LDFA and MPTA measurements. These findings suggest that differences in category distributions may partly reflect measurement‐related variability rather than genuine anatomical variation. Consequently, the application of strict categorical cut‐off values in alignment strategies for total knee arthroplasty could introduce clinically significant inaccuracies. Level of Evidence N/A.

Schlagwörter

Stichwörter der Autor:innen

alignmentcoronal plane alignment of the knee (CPAK)knee phenotypesobserver variationreproducibility of results

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery and Traumatology, Hospital General Universitario Reina Sofía, Murcia, Spain.
  • Instituto de Cirugía Avanzada de la Rodilla (ICAR), Murcia, Spain.
  • Department of Surgery, Paediatrics and Obstetrics & Gynaecology, Faculty of Medicine (University of Murcia), Murcia, Spain.
  • Instituto Murciano de Investigación Biosanitaria Pascual Parrilla (IMIB), Murcia, Spain.
  • Olympia Medical Centre, Madrid, Spain.
  • Department of Orthopaedic Surgery and Traumatology, Hospital Clínico Universitario Virgen de la Arrixaca, Murcia, Spain.

ORCID-Profile: Vicente Jesús León-Muñoz, Joaquín Moya-Angeler, Fernando Santonja-Medina, Francisco Lajara-Marco, Ahmet Şenel, Hong Yeol Yang

Förderung

  • None

Zitieren

APA

León-Muñoz, V. J., Moya-Angeler, J., Santonja-Medina, F., Lajara-Marco, F., Şenel, A., Yang, H. Y., & Hurtado-Avilés, J. (2026). Sensitivity to measurement errors in the CPAK classification may affect the accuracy of coronal knee alignment classification. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.70438

Vancouver

León-Muñoz VJ, Moya-Angeler J, Santonja-Medina F, Lajara-Marco F, Şenel A, Yang HY, et al. Sensitivity to measurement errors in the CPAK classification may affect the accuracy of coronal knee alignment classification. Knee Surgery, Sports Traumatology, Arthroscopy. 2026. doi:10.1002/ksa.70438

BibTeX
@article{LenMuoz2026,
  author = {León-Muñoz, Vicente Jesús and Moya-Angeler, Joaquín and Santonja-Medina, Fernando and Lajara-Marco, Francisco and Şenel, Ahmet and Yang, Hong Yeol and Hurtado-Avilés, José},
  title = {Sensitivity to measurement errors in the CPAK classification may affect the accuracy of coronal knee alignment classification},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2026},
  doi = {10.1002/ksa.70438}
}
Kostenlos starten →