Übersichtsarbeit in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 19.02.2026. Verfasst von Brandon K Couch und 4 weiteren Autor:innen. Beteiligte Einrichtung: Fondren Orthopedic Group, Texas Orthopedic Hospital, Houston, Texas, USA. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Knee Joint. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 155 Literaturangaben. Gefördert von: the Fondren Orthopedic Research Institute at the Texas Orthopedic Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

As robotic‐assisted total knee arthroplasty (RATKA) continues to expand in clinical adoption, accurate and transparent reporting of surgical technique is critical for reproducibility and meaningful comparison of outcomes. This study aimed to assess the adequacy of reporting RATKA methods, with a focus on alignment and balancing philosophies; hypothesising that current RATKA literature may be variant and insufficient in reporting.

Methods

A PubMed search conducted on 10 March 2025, identified studies from the top 50 orthopedic journals ranked by impact factor using the terms ‘robot’ and ‘total knee arthroplasty’. Eligible studies included those reporting outcomes of primary RATKA procedures using patient‐reported, surgical, medical, or radiographic data. A total of 134 studies met inclusion criteria and were assessed for reporting completeness across three domains: technology, technique and surgeon. The technology domain included the robotic system, software version, and implant; the technique domain included alignment philosophy, coronal and sagittal alignment boundaries, and quantitative soft tissue balancing goals; and the surgeon domain included surgeon experience and case volume.

Results

Only six studies (4.5%) reported all technology domain variables, while the robotic system was identified in 97.0%, software version in 4.5%, and implant in 89.6%. For the technique domain, 32 studies (23.9%) reported all variables, with alignment philosophy reported in 79.1%, coronal boundaries in 68.7%, sagittal boundaries in 42.5%, and soft tissue balancing goals in 47.8%. Only 17 studies (12.7%) reported both surgeon‐related variables, with experience and volume documented in 50.0% and 16.4% of studies, respectively.

Conclusion

These findings reveal that key methodological aspects of RATKA, particularly alignment philosophy, balancing strategy, and surgeon experience, are inconsistently reported in the literature. As robotic technology becomes increasingly integrated into total knee arthroplasty, standardised and comprehensive reporting is essential to ensure reproducibility, enable accurate comparison of outcomes, and promote evidence‐based adoption of RATKA techniques. Level of Evidence Level V.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresKnee JointHumans

Stichwörter der Autor:innen

alignment philosophyrobotic‐assisted total knee arthroplasty (RATKA)soft tissue balancingsurgical technique reporting

Autor:innen und Institutionen

  • Fondren Orthopedic Group, Texas Orthopedic Hospital, Houston, Texas, USA.

ORCID-Profile: Corey F Hryc

Förderung

  • the Fondren Orthopedic Research Institute at the Texas Orthopedic Hospital

Zitieren

APA

Couch, B. K., Pfeil, A. N., Hryc, C. F., LeBrun, D. G., & Ihekweazu, U. N. (2026). Alignment boundaries and soft tissue balancing goals are inconsistently reported in robotic‐assisted total knee arthroplasty studies: A narrative methodological review. Knee Surgery, Sports Traumatology, Arthroscopy, 34(10), 3675-3690. https://doi.org/10.1002/ksa.70331

Vancouver

Couch BK, Pfeil AN, Hryc CF, LeBrun DG, Ihekweazu UN. Alignment boundaries and soft tissue balancing goals are inconsistently reported in robotic‐assisted total knee arthroplasty studies: A narrative methodological review. Knee Surgery, Sports Traumatology, Arthroscopy. 2026;34(10):3675-3690. doi:10.1002/ksa.70331

BibTeX
@article{Couch2026,
  author = {Couch, Brandon K and Pfeil, Allyson N and Hryc, Corey F and LeBrun, Drake G and Ihekweazu, Ugonna N},
  title = {Alignment boundaries and soft tissue balancing goals are inconsistently reported in robotic‐assisted total knee arthroplasty studies: A narrative methodological review},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2026},
  volume = {34},
  number = {10},
  pages = {3675--3690},
  doi = {10.1002/ksa.70331}
}
Kostenlos starten →