EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Knee hyperextension is a sign of through‐range laxity and may be effectively managed without routine joint line distalisation in a robotic functional alignment workflow

Anton Lambers iD, Serene Lee iD, Kate Langton, Dermot Collopy iD, Gavin Clark iD

Knee Surgery, Sports Traumatology, Arthroscopy · 2026-08 · 34 (8) · 2906-2915

DOI: 10.1002/ksa.70203 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 01.12.2025. Verfasst von Anton Lambers und 4 weiteren Autor:innen. Beteiligte Einrichtung: Medical School, The University of Western Australia, Perth, Western Australia, Australia. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Knee Joint, Joint Instability. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Traditional management of hyperextension deformity in total knee arthroplasty (TKA) involves routine under‐resection of distal femoral bone to lower the joint line and close the extension gap. This study aimed to assess how a robotic functional alignment (FA) workflow with pre‐resection gap assessment managed hyperextending knees to achieve balance compared to controls.

Methods

A retrospective analysis of a prospective registry was performed using a single implant/robotic platform, two surgeons, between 2016 and 2023. 100 hyperextending TKA patients with hyperextension of 5° or more were compared to a control group of 1881 patients with 0°–10° of fixed flexion contracture.

Results

The hyperextension group had a greater maximum flexion ROM (137° vs. 132°) compared to controls. All four mean start‐of‐case gaps (medial and lateral in flexion and extension) were larger for the hyperextension patients by 0.7–1.2 mm. The femoral joint line was not routinely distalised by a clinically significant amount in the hyperextension patients (0.3 mm difference in means; 0.6 mm vs. 0.3 mm. The hyperextension cohort had relative tibial under‐resection (4.8 mm vs. 5.4 mm; p < 0.001) and additional insert thickness (11.2 vs. 10.3 mm; p < 0.001) resulting in an overall mean tibial joint line elevation of 1.5 mm greater than controls. At the 1‐year mark, there was no difference between groups when assessing range of motion ( p > 0.05) and forgotten joint score (FJS, p > 0.05). Two patients had hyperextension recurrence at 1‐year review, measured at –2° and –5°.

Conclusions

Hyperextending arthritic knees may not require routine distalisation of the femoral joint line to achieve balance and close the extension gap. These knees have a global laxity that can often be effectively managed with predominantly tibial sided changes. Level of Evidence Level III, therapeutic retrospective comparative study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresKnee JointJoint InstabilityHumansRetrospective StudiesRange of Motion, ArticularFemaleMaleAgedOsteoarthritis, KneeMiddle AgedWorkflow

Stichwörter der Autor:innen

functional alignmentgap assessmenthyperextension deformityrobotic‐assisted total knee arthroplastytotal knee arthroplasty

Autor:innen und Institutionen

  • Medical School, The University of Western Australia, Perth, Western Australia, Australia.
  • Department of Orthopaedics, Northeast Health Wangaratta, Wangaratta, Victoria, Australia.
  • Perth Hip and Knee Clinic, Perth, Australia.
  • St John of God Subiaco, Murdoch and Midland Hospitals, Perth, Western Australia, Australia.

ORCID-Profile: Anton Lambers, Serene Lee, Dermot Collopy, Gavin Clark

Zitieren

APA

Lambers, A., Lee, S., Langton, K., Collopy, D., & Clark, G. (2026). Knee hyperextension is a sign of through‐range laxity and may be effectively managed without routine joint line distalisation in a robotic functional alignment workflow. Knee Surgery, Sports Traumatology, Arthroscopy, 34(8), 2906-2915. https://doi.org/10.1002/ksa.70203

Vancouver

Lambers A, Lee S, Langton K, Collopy D, Clark G. Knee hyperextension is a sign of through‐range laxity and may be effectively managed without routine joint line distalisation in a robotic functional alignment workflow. Knee Surgery, Sports Traumatology, Arthroscopy. 2026;34(8):2906-2915. doi:10.1002/ksa.70203

BibTeX
@article{Lambers2026,
  author = {Lambers, Anton and Lee, Serene and Langton, Kate and Collopy, Dermot and Clark, Gavin},
  title = {Knee hyperextension is a sign of through‐range laxity and may be effectively managed without routine joint line distalisation in a robotic functional alignment workflow},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2026},
  volume = {34},
  number = {8},
  pages = {2906--2915},
  doi = {10.1002/ksa.70203}
}
Kostenlos starten →