EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Retention or sacrifice of posterior cruciate ligament has no effect on in vitro kinematics in medial pivot total knee arthroplasty

Johanna-Maria Simon iD, Thomas Richard Niethammer, Christoph Thorwächter, Matthias Woiczinski, Felix Endres, Peter Ernst Müller, Boris Michael Holzapfel, Leandra Bauer

Knee Surgery, Sports Traumatology, Arthroscopy · 2026-06 · 34 (6) · 2144-2151

DOI: 10.1002/ksa.70121 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 28.10.2025. Verfasst von Johanna-Maria Simon und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital Munich, LMU Munich, Munich, German…. Hauptthemen laut MEDLINE: Posterior Cruciate Ligament, Arthroplasty, Replacement, Knee, Knee Joint, Knee Prosthesis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Förderprogramm für Forschung und Lehre (FöFoLe) by the medical faculty of the University of Munich (LMU).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The role of the posterior cruciate ligament remains debated, particularly in medial pivot designs intended to functionally substitute the posterior cruciate ligament. While some manufacturers recommend posterior cruciate ligament resection, evidence regarding its biomechanical relevance in medial pivot total knee arthroplasty is limited.

Methods

This in vitro study evaluated knee kinematics in seven cadaveric knees implanted with a mechanically aligned medial pivot total knee arthroplasty (GMK Sphere). Each specimen was tested dynamically (30°–130° flexion) under three conditions: native knee, medial pivot with posterior cruciate ligament retained and with posterior cruciate ligament resected. Kinematic parameters (anterior‐posterior translation, tibial rotation, patellar shift and tilt) and quadriceps force were recorded using a 3D optoelectronic system in a validated dynamic knee rig.

Results

Compared to native knees, medial pivot total knee arthroplasty increased anterior tibial translation and altered tibial rotation ( p < 0.001), regardless of posterior cruciate ligament status. Patellar shift showed less medialization in deep flexion with posterior cruciate ligament retention in comparison to native conditions ( R 2 = 0.20, p < 0.001). Quadriceps force differed from the native state but was unaffected by posterior cruciate ligament status; force patterns were primarily determined by the native knee ( R ² = 0.90, p < 0.001).

Conclusion

Posterior cruciate ligament retention in medial pivot total knee arthroplasty does not significantly affect femorotibial or patellofemoral kinematics. The highly congruent medial design appears to reduce the functional importance of the posterior cruciate ligament. Therefore, intraoperative decisions regarding posterior cruciate ligament management may be made less on concerns about kinematic compromise. Level of evidence N/A.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Posterior Cruciate LigamentArthroplasty, Replacement, KneeKnee JointKnee ProsthesisHumansBiomechanical PhenomenaRange of Motion, ArticularCadaverFemaleMaleAgedRotationAged, 80 and overProsthesis DesignMiddle AgedTibia

Stichwörter der Autor:innen

biomechanical studyknee kinematicsmedial pivotposterior cruciate ligamenttotal knee arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital Munich, LMU Munich, Munich, Germany.
  • Experimental Orthopaedics, University Hospital Jena, Campus Eisenberg, Waldkliniken Eisenberg, Friedrich-Schiller-University Jena, Jena, Germany.

ORCID-Profile: Johanna-Maria Simon

Förderung

  • Förderprogramm für Forschung und Lehre (FöFoLe) by the medical faculty of the University of Munich (LMU)

Zitieren

APA

Simon, J. M., Niethammer, T. R., Thorwächter, C., Woiczinski, M., Endres, F., Müller, P. E., Holzapfel, B. M., & Bauer, L. (2026). Retention or sacrifice of posterior cruciate ligament has no effect on in vitro kinematics in medial pivot total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy, 34(6), 2144-2151. https://doi.org/10.1002/ksa.70121

Vancouver

Simon JM, Niethammer TR, Thorwächter C, Woiczinski M, Endres F, Müller PE, et al. Retention or sacrifice of posterior cruciate ligament has no effect on in vitro kinematics in medial pivot total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy. 2026;34(6):2144-2151. doi:10.1002/ksa.70121

BibTeX
@article{Simon2026,
  author = {Simon, Johanna-Maria and Niethammer, Thomas Richard and Thorwächter, Christoph and Woiczinski, Matthias and Endres, Felix and Müller, Peter Ernst and Holzapfel, Boris Michael and Bauer, Leandra},
  title = {Retention or sacrifice of posterior cruciate ligament has no effect on in vitro kinematics in medial pivot total knee arthroplasty},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2026},
  volume = {34},
  number = {6},
  pages = {2144--2151},
  doi = {10.1002/ksa.70121}
}
Kostenlos starten →