Comparative diagnostic accuracy of next‐generation sequencing in different specimen types for periprosthetic joint infection: A systematic review and meta‐analysis
Knee Surgery, Sports Traumatology, Arthroscopy · 2026-05 · 34 (5) · 1725-1739
DOI: 10.1002/ksa.70095 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 17.10.2025. Verfasst von Lina Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Infectious Diseases, Affiliated Hospital of Qingdao University, Qingdao, Shandong, China. Hauptthemen laut MEDLINE: Prosthesis-Related Infections, High-Throughput Nucleotide Sequencing. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Discrepancies in next‐generation sequencing (NGS) results across synovial fluid, periprosthetic tissues and implant sonicate fluid pose a significant clinical challenge in diagnosing periprosthetic joint infection (PJI). We conducted a systematic review and meta‐analysis to compare the diagnostic accuracy of these NGS sample types for PJI.
Methods
This study adhered to the Preferred Reporting Items for Systematic Reviews and Meta‐Analyses guidelines. A comprehensive literature search was conducted in PubMed, EMBASE and the Cochrane Library databases from inception to 1 June 2025. Two independent reviewers performed data extraction and assessed study quality using the Quality Assessment of Diagnostic Accuracy Studies‐2 tool. For each specimen type, we estimated the pooled sensitivity and specificity, summary receiver operating characteristic (SROC) curve and the area under the SROC curve (AUC).
Results
Following screening, 18 studies were included. Pooled sensitivities of NGS for PJI diagnosis were as follows: synovial fluid 0.86 (95% confidence interval [CI]: 0.79–0.91), periprosthetic tissue 0.86 (95% CI: 0.69–0.95) and sonicate fluid 0.89 (95% CI: 0.77–0.95). Corresponding specificities were 0.94 (95% CI: 0.91–0.96), 0.98 (95% CI: 0.85–1.00) and 0.96 (95% CI: 0.91–0.98). AUCs were 0.93 (0.89–0.95), 0.96 (0.88–0.97) and 0.96 (0.88–0.97), respectively. Pairwise comparisons of AUCs showed no statistically significant differences ( p > 0.05).
Conclusions
This meta‐analysis suggests that NGS of sonicate fluid demonstrates higher sensitivity compared to NGS of synovial fluid or periprosthetic tissue, while maintaining strong specificity, making it valuable for detecting infection. Periprosthetic tissue NGS demonstrated exceptional specificity and acceptable sensitivity, making it valuable for confirming infection. All specimens show clinically useful AUC values. Sonicate fluid shows promise, but specimen selection warrants careful consideration of the sensitivity‐specificity trade‐off in clinical practice and requires validation of clinical utility due to the absence of a perfect PJI diagnostic gold standard and the risk of false positives. Level of Evidence Level II.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Infectious Diseases, Affiliated Hospital of Qingdao University, Qingdao, Shandong, China.
- Department of Joint Surgery, Yantai City Yantaishan Hospital, Yantai, Shandong, China.
- Department of Orthopaedics, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
ORCID-Profile: Kun Song
Zitieren
APA
Wang, L., Feng, S., Zhao, Z., Zhao, Y., Dong, S., Cao, L., & Song, K. (2026). Comparative diagnostic accuracy of next‐generation sequencing in different specimen types for periprosthetic joint infection: A systematic review and meta‐analysis. Knee Surgery, Sports Traumatology, Arthroscopy, 34(5), 1725-1739. https://doi.org/10.1002/ksa.70095
Vancouver
Wang L, Feng S, Zhao Z, Zhao Y, Dong S, Cao L, et al. Comparative diagnostic accuracy of next‐generation sequencing in different specimen types for periprosthetic joint infection: A systematic review and meta‐analysis. Knee Surgery, Sports Traumatology, Arthroscopy. 2026;34(5):1725-1739. doi:10.1002/ksa.70095
BibTeX
@article{Wang2026,
author = {Wang, Lina and Feng, Shangxiang and Zhao, Zhongyuan and Zhao, Yuchi and Dong, Shengjie and Cao, Li and Song, Kun},
title = {Comparative diagnostic accuracy of next‐generation sequencing in different specimen types for periprosthetic joint infection: A systematic review and meta‐analysis},
journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
year = {2026},
volume = {34},
number = {5},
pages = {1725--1739},
doi = {10.1002/ksa.70095}
}
EUVIMED