EUVIMEDEUVIMED entdecken
BeobachtungsstudieVergleichsstudieMultizentrische Studie

Functional alignment improves femoral joint line obliquity preservation in comparison with the classical measured resection technique

Oriol Pujol iD, Pedro Hinarejos iD, Albert Pons iD, Ernest Famada, Angela Zumel iD, Matías Novillo iD, Juan Erquicia iD, Joan Leal-Blanquet iD

Knee Surgery, Sports Traumatology, Arthroscopy · 2026-06 · 34 (6) · 2121-2129

DOI: 10.1002/ksa.70092 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 15.10.2025. Verfasst von Oriol Pujol und 7 weiteren Autor:innen. Beteiligte Einrichtung: Knee Surgery Unit, Orthopaedic Surgery Department, Vall d'Hebron University Hospital, Universitat Autònoma de Barcelona (Departament de Cirurgia), Ba…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Femur, Robotic Surgical Procedures, Knee Joint. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

(1) To analyse the femoral anatomical–mechanical axis (AA–MA) and posterior condylar–transepicondylar axis (PCA–TEA) relationships using computed tomography (CT)‐based measurements. (2) To quantify the coronal and axial errors that would occur when positioning the femoral component using mechanically aligned TKA modelled as 5° of valgus from the AA and 3° of external rotation from the PCA. (3) To compare coronal and rotational femoral positioning between this systematic approach and robotic‐assisted functionally aligned TKA.

Methods

It is a multicentric cross‐sectional observational study. Preoperative CT scans of 318 patients were analysed to determine AA–MA and PCA–TEA relationships. Then, femoral positioning was simulated, intending a measured‐resection mechanical aligned TKA defined as 5° of valgus from the AA and 3° of external rotation from the PCA. It was compared with the real femoral component placement performed in each patient using robotic‐assisted functionally aligned TKA.

Results

Mean AA–MA relationship was 6.0 ± 0.9° and mean PCA–TEA was 3.1 ± 1.8°. In measured‐resection, mechanically aligned TKA, 74.4% and 45.8% of patients would present a femoral component implanted in varus from the MA and internal rotation from the TEA, respectively. Functional alignment was significantly closer to the native LDFA than mechanical alignment (2.0° vs 3.5°). With mechanical alignment, 45.8% of femoral components would be implanted in internal rotation from the TEA, compared to only 8.8% with functional alignment.

Conclusions

Measured resection based on average population data (5° of valgus from the AA and 3° of external rotation from the PCA) may result in a considerable proportion of femoral components implanted in varus and internal rotation. In contrast, robotic‐assisted functionally aligned TKA provided significantly improved restoration of the native femoral joint line obliquity and effectively prevented excessive internal rotation. Level of Evidence Level IV.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeFemurRobotic Surgical ProceduresKnee JointOsteoarthritis, KneeHumansTomography, X-Ray ComputedCross-Sectional StudiesFemaleMaleAgedMiddle Aged

Stichwörter der Autor:innen

alignmentfemurindividualizedjoint linetotal knee arthroplasty (TKA)

Autor:innen und Institutionen

  • Knee Surgery Unit, Orthopaedic Surgery Department, Vall d'Hebron University Hospital, Universitat Autònoma de Barcelona (Departament de Cirurgia), Barcelona, Spain.
  • Knee Surgery Unit, iMove Traumatology, Barcelona, Spain.
  • Knee Surgery Unit, Orthopaedic Surgery Department, Hospital del Mar, Universitat Autònoma de Barcelona, Barcelona, Spain.
  • Knee Surgery Unit, Orthopaedic Surgery Department, Hospital Sant Joan de Déu de Manresa - Fundació Althaia, Universitat de Vic, Manresa, Spain.

ORCID-Profile: Oriol Pujol, Pedro Hinarejos, Albert Pons, Angela Zumel, Matías Novillo, Juan Erquicia, Joan Leal-Blanquet

Zitieren

APA

Pujol, O., Hinarejos, P., Pons, A., Famada, E., Zumel, A., Novillo, M., Erquicia, J., & Leal-Blanquet, J. (2026). Functional alignment improves femoral joint line obliquity preservation in comparison with the classical measured resection technique. Knee Surgery, Sports Traumatology, Arthroscopy, 34(6), 2121-2129. https://doi.org/10.1002/ksa.70092

Vancouver

Pujol O, Hinarejos P, Pons A, Famada E, Zumel A, Novillo M, et al. Functional alignment improves femoral joint line obliquity preservation in comparison with the classical measured resection technique. Knee Surgery, Sports Traumatology, Arthroscopy. 2026;34(6):2121-2129. doi:10.1002/ksa.70092

BibTeX
@article{Pujol2026,
  author = {Pujol, Oriol and Hinarejos, Pedro and Pons, Albert and Famada, Ernest and Zumel, Angela and Novillo, Matías and Erquicia, Juan and Leal-Blanquet, Joan},
  title = {Functional alignment improves femoral joint line obliquity preservation in comparison with the classical measured resection technique},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2026},
  volume = {34},
  number = {6},
  pages = {2121--2129},
  doi = {10.1002/ksa.70092}
}
Kostenlos starten →