EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Robotic arm‐assisted total knee arthroplasty reduces postoperative inflammatory response and blood loss compared to manual total knee arthroplasty: A matched‐pairs analysis of 688 patients

Dirk Müller iD, Igor Lazic iD, Benjamin Schloßmacher iD, Vincent Lallinger iD, Michael T Hirschmann iD, Rüdiger von Eisenhart-Rothe iD, Florian Pohlig iD

Knee Surgery, Sports Traumatology, Arthroscopy · 2026

DOI: 10.1002/ksa.70054 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2026. Verfasst von Dirk Müller und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Blood Loss, Surgical, Postoperative Complications. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Robotic arm‐assisted total knee arthroplasty (raTKA) has demonstrated several advantages over manual TKA (mTKA), including enhanced early recovery. Reduced soft tissue trauma and avoidance of femoral intramedullary canal opening have been hypothesised to lower the systemic inflammatory response. However, findings from previous small‐cohort studies have been inconsistent. This study aimed to evaluate postoperative systemic inflammation in a large patient cohort.

Methods

Patients who underwent raTKA using the Mako® system were matched with patients who received mTKA based on gender, American Society of Anesthesiologists score, age and body mass index. This matching process resulted in two comparable cohorts, each comprising 344 patients. Blood samples were collected preoperatively, 6 h postoperatively, and on postoperative Days 3 and 5. Measurements included C‐reactive protein (CRP), white blood cell count (WBC) and calculated blood loss.

Results

The highest CRP levels were observed on postoperative Day 3 in both groups. The median CRP increase was significantly lower in the raTKA group compared with the mTKA group on Day 3 (4.4 vs. 5.3 mg/dL; p = 0.002) and slightly lower on Day 5 (3.5 vs. 3.8 mg/dL; p = 0.349). The WBC count peaked at 6 h postoperatively in both groups before steadily declining, with no significant difference between groups. The median operation time was significantly longer in the raTKA group (92 vs. 86 min; p < 0.001). Despite a longer surgical duration, the median blood loss was significantly lower in the raTKA group (653 vs. 729 mL; p = 0.005).

Conclusion

In the largest comparative analysis to date, raTKA was linked to significantly lower postoperative CRP levels than mTKA. Reduced soft tissue trauma, avoidance of femoral intramedullary canal violation and significantly lower blood loss may all contribute to a diminished systemic inflammatory response, potentially explaining the improved early functional outcomes observed with raTKA. Level of Evidence Level III, retrospective comparative study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresBlood Loss, SurgicalPostoperative ComplicationsInflammationOsteoarthritis, KneeHumansMaleFemaleAgedC-Reactive ProteinMiddle AgedLeukocyte CountMatched-Pair AnalysisRetrospective Studies

Stichwörter der Autor:innen

C‐reactive protein (CRP)blood lossmanual total knee arthroplasty (mTKA)matched‐pairs analysisrobotic arm‐assisted total knee arthroplasty (raTKA)systemic inflammatory response

Substanzen

C-Reactive Protein

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), Bruderholz, Switzerland.
  • Schoen Clinic Munich, Munich, Germany.

ORCID-Profile: Dirk Müller, Igor Lazic, Benjamin Schloßmacher, Vincent Lallinger, Michael T Hirschmann, Rüdiger von Eisenhart-Rothe, Florian Pohlig

Zitieren

APA

Müller, D., Lazic, I., Schloßmacher, B., Lallinger, V., Hirschmann, M. T., von Eisenhart-Rothe, R., & Pohlig, F. (2026). Robotic arm‐assisted total knee arthroplasty reduces postoperative inflammatory response and blood loss compared to manual total knee arthroplasty: A matched‐pairs analysis of 688 patients. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.70054

Vancouver

Müller D, Lazic I, Schloßmacher B, Lallinger V, Hirschmann MT, von Eisenhart-Rothe R, et al. Robotic arm‐assisted total knee arthroplasty reduces postoperative inflammatory response and blood loss compared to manual total knee arthroplasty: A matched‐pairs analysis of 688 patients. Knee Surgery, Sports Traumatology, Arthroscopy. 2026. doi:10.1002/ksa.70054

BibTeX
@article{Mller2026,
  author = {Müller, Dirk and Lazic, Igor and Schloßmacher, Benjamin and Lallinger, Vincent and Hirschmann, Michael T and von Eisenhart-Rothe, Rüdiger and Pohlig, Florian},
  title = {Robotic arm‐assisted total knee arthroplasty reduces postoperative inflammatory response and blood loss compared to manual total knee arthroplasty: A matched‐pairs analysis of 688 patients},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2026},
  doi = {10.1002/ksa.70054}
}
Kostenlos starten →