Comparable clinical outcomes in functionally aligned computer‐assisted and image‐based robotic assisted total knee arthroplasty
Knee Surgery, Sports Traumatology, Arthroscopy · 2026
DOI: 10.1002/ksa.70023 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2026. Verfasst von Stefano Seracchioli und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Azienda Ospedaliero-Universitaria di Modena, University of Modena and Reggio-Emilia, Modena, Italy. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Surgery, Computer-Assisted, Osteoarthritis, Knee. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To determine the clinical outcomes differences and complications in two comparable groups of patients undergoing computer aided surgery (CAS) and robotic‐assisted (RA) posterior stabilised (PS) total knee arthroplasty (TKA) following functional alignment (FA) principles with tibial pre‐cut at a minimum of 4‐year follow‐up.
Methods
This retrospective, monocentric and observational study included 94 consecutive patients undergoing PS TKA performed with CAS and RA‐TKA following FA principles, between January 2017 and January 2020. Patients were followed with radiological and clinical assessment and evaluated with the Forgotten Joint Score‐12 (FJS‐12), Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS‐JR) and the 5‐Level Likert Scale (5‐LLS).
Results
Out of 94 patients two were lost to follow‐up and one deceased in the robotic branch, eight patients were lost to follow‐up and two were deceased in the navigated branch. Hereby, a total of 84 patients (87 knees) with a mean age of 69.2 ± 8.4 years were considered. A total of 40 cases were included in the CAS group; 44 cases were included in the RA‐TKA group. No revisions were performed in any of the two groups, resulting in an overall Kaplan‐Meyer survivorship rate of 100% for both cohorts. At last follow‐up, no statistically significant differences were recorded between CAS and RA‐TKA relative to FJS‐12, KOOS‐JR and 5‐LLS (FJS‐12: 89.4 ± 9.5 vs. 88.3 ± 13.4; KOOS‐JR: 88.0 ± 10.2 vs 86.2 ± 11.5; 5‐LLS 4.4 ± 1.7 vs 4.6 ± 2.1) respectively.
Conclusions
No significant outcomes differences and complications were detected between patients undergoing PS‐TKA performed with either CAS and RA at a minimum 4‐year follow‐up. TKA performed with a patient‐specific FA technique and with a soft tissue‐preserving approach, showed excellent results with both CAS and RA‐TKA. Level of Evidence Level III.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics and Traumatology, Azienda Ospedaliero-Universitaria di Modena, University of Modena and Reggio-Emilia, Modena, Italy.
- Department of Medical and Surgical Sciences for Mother, Child and Adult, University of Modena and Reggio-Emilia, Modena, Italy.
- Department of Orthopaedic Surgery, School of Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
ORCID-Profile: Stefano Seracchioli, Francesco Zambianchi
Zitieren
APA
Seracchioli, S., Zambianchi, F., Clemenza, S., Clò, M., Costantini, R. C., & Catani, F. (2026). Comparable clinical outcomes in functionally aligned computer‐assisted and image‐based robotic assisted total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.70023
Vancouver
Seracchioli S, Zambianchi F, Clemenza S, Clò M, Costantini RC, Catani F. Comparable clinical outcomes in functionally aligned computer‐assisted and image‐based robotic assisted total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy. 2026. doi:10.1002/ksa.70023
BibTeX
@article{Seracchioli2026,
author = {Seracchioli, Stefano and Zambianchi, Francesco and Clemenza, Sebastiano and Clò, Mattia and Costantini, Riccardo Cuoghi and Catani, Fabio},
title = {Comparable clinical outcomes in functionally aligned computer‐assisted and image‐based robotic assisted total knee arthroplasty},
journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
year = {2026},
doi = {10.1002/ksa.70023}
}