EUVIMEDEUVIMED entdecken
Vergleichsstudie

Artificial anterolateral ligament reconstruction provides similar knee kinematics as compared to an autologous reconstruction and a lateral extra‐articular tenodesis

Hua Ying iD, Xianghui Li, Gai Yao, Yuning Su, Xiangjun Hu, Rongshan Cheng, Tsung-Yuan Tsai, Zimin Wang iD

Knee Surgery, Sports Traumatology, Arthroscopy · 2025

DOI: 10.1002/ksa.12811 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025. Verfasst von Hua Ying und 7 weiteren Autor:innen. Beteiligte Einrichtung: Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Ji…. Hauptthemen laut MEDLINE: Tenodesis, Anterior Cruciate Ligament Reconstruction, Knee Joint, Anterior Cruciate Ligament. Die Arbeit nennt 48 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Commission of Shanghai Municipality, Fundamental Research Funds for the Central Universities.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

We biomechanically compared three anterolateral procedures (artificial‐anterolateral ligament [ALL] reconstruction, autologous‐ALL reconstruction and lateral extra‐articular tenodesis [LET]) in knees with anterior cruciate ligament (ACL) and anterolateral complex (ALC) injuries when combined with nonanatomic artificial ACL reconstruction.

Methods

Eight cadaveric knees were tested robotically at time‐zero: (1) intact, (2) ACL + ALC deficient, (3) ACL reconstruction + artificial‐ALL reconstruction, (4) ACL reconstruction + autologous‐ALL reconstruction, (5) ACL reconstruction+LET. Each state was tested under 3 loads: (1) a 89N anterior tibial (AT) loading to test AT translation (ATT) at full extension (FE), 30°, 60° and 90°, (2) a 5N·m internal rotation (IR) tibial torque to test tibial IR at FE, 15°, 30° and 45°, (3) a simulated pivot‐shift test consisting of a combined 5 N·m IR tibial torque and 7 N·m valgus load to test ATT and IR at FE, 15°, 30° and 45°.

Results

ACL + ALC deficiency impaired anteroposterior and rotational knee stability across all conditions. Under 89 N AT loading, the anterior instability was fully restored by ACL reconstruction + artificial‐ALL reconstruction (n.s.) and partially by ACL reconstruction + autologous‐ALL reconstruction and ACL reconstruction + LET, with significant differences from the intact state at 30° ( p = 0.019) and 60° ( p = 0.011) in the ACL reconstruction + autologous‐ALL reconstruction state and at 30° ( p = 0.032) and 60° ( p = 0.018) in the ACL reconstruction+LET state. Under 5 N·m IR tibial torque, the internal rotational instability was fully restored by ACL reconstruction+artificial‐ALL reconstruction and ACL reconstruction + LET (n.s.) and partially by ACL reconstruction + autologous‐ALL reconstruction, with significant differences from the intact state at FE ( p = 0.044) and 15° ( p = 0.049). During simulated pivot‐shift testing, all three procedures fully restored native kinematics with no significant differences observed (n.s.).

Conclusions

Artificial‐ALL reconstruction, autologous‐ALL reconstruction, and LET similarly restored native knee kinematics in ACL + ALC deficient knees when combined with artificial ACL reconstruction at time‐zero. Level of Evidence Level V, laboratory study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TenodesisAnterior Cruciate Ligament ReconstructionKnee JointAnterior Cruciate LigamentKnee InjuriesHumansBiomechanical PhenomenaCadaverAnterior Cruciate Ligament InjuriesMaleFemaleTransplantation, AutologousMiddle AgedAged

Stichwörter der Autor:innen

ACLRALLRLETknee stabilitysynthetic grafts

Autor:innen und Institutionen

  • Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
  • School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China.
  • The Fifth Medical Center of Chinese PLA General Hospital, Beijing, China.
  • Department of Rehabilitation Medicine, Zhongshan Hospital, Fudan University, Shanghai, China.

ORCID-Profile: Hua Ying, Zimin Wang

Förderung

  • National Natural Science Foundation of China
  • Science and Technology Commission of Shanghai Municipality
  • Fundamental Research Funds for the Central Universities
  • Pudong Science Technology and Economy Commission
  • Shanghai Jiao Tong University "New Young Teachers Startup Plan
  • Shanghai Jiao Tong University "New Young Teachers Startup Plan"

Zitieren

APA

Ying, H., Li, X., Yao, G., Su, Y., Hu, X., Cheng, R., Tsai, T. Y., & Wang, Z. (2025). Artificial anterolateral ligament reconstruction provides similar knee kinematics as compared to an autologous reconstruction and a lateral extra‐articular tenodesis. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12811

Vancouver

Ying H, Li X, Yao G, Su Y, Hu X, Cheng R, et al. Artificial anterolateral ligament reconstruction provides similar knee kinematics as compared to an autologous reconstruction and a lateral extra‐articular tenodesis. Knee Surgery, Sports Traumatology, Arthroscopy. 2025. doi:10.1002/ksa.12811

BibTeX
@article{Ying2025,
  author = {Ying, Hua and Li, Xianghui and Yao, Gai and Su, Yuning and Hu, Xiangjun and Cheng, Rongshan and Tsai, Tsung-Yuan and Wang, Zimin},
  title = {Artificial anterolateral ligament reconstruction provides similar knee kinematics as compared to an autologous reconstruction and a lateral extra‐articular tenodesis},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  doi = {10.1002/ksa.12811}
}
Kostenlos starten →