EUVIMEDEUVIMED entdecken
Systematische ÜbersichtVergleichsstudieMetaanalyseOpen Access · CC BY 4.0

Technology‐assisted revision knee arthroplasty reduces radiographic outliers compared with standard revision knee surgery: A systematic review

Matteo Innocenti iD, Filippo Leggieri iD, Simon N van Laarhoven iD, Tommy de Windt iD, Roberto Civinini iD, Gijs G van Hellemondt iD

Knee Surgery, Sports Traumatology, Arthroscopy · 2025-10 · 33 (10) · 3606-3620

DOI: 10.1002/ksa.12748 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 24.07.2025. Verfasst von Matteo Innocenti und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Orthopaedics, University of Florence, Florence, Italy. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Reoperation, Robotic Surgical Procedures. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim of this systematic review was to evaluate the outcomes and complications associated with technology‐assisted revision total knee arthroplasty (revTKA).

Methods

A systematic search of PubMed, EMBASE, Web of Science and the Cochrane Library was conducted from inception to 31 October 2024. The inclusion criteria were experimental or observational studies with ≥10 patients undergoing robotic revTKA, evaluating clinical and/or radiological outcomes and/or complication rates. The exclusion criteria were isolated patellar revision, in vitro studies, letters to the editor, book chapters, conference papers, and studies without accessible full text. Each study was given a quality rating using the methodological index for non‐randomised studies (MINORS). The included studies were divided into those reporting revision from TKA and those from unicompartmental knee arthroplasty (UKA), for both qualitative and quantitative synthesis. Random‐effects meta‐analyses were performed where appropriate. Mean differences with 95% confidence intervals (CIs) were calculated for radiographic parameters. Heterogeneity was assessed using the I 2 statistic.

Results

Across 20 studies (795 cases), 10 assessed revTKA and 10 examined revUKA. Of the revTKA studies, four were comparative cohorts, while among the revUKA studies, seven were comparative cohorts. Technology‐assisted revTKA showed fewer outliers in hip–knee–ankle angle (13.3% [95% CI, 8.7%–19.0%] vs. 26.1% [95% CI, 16.3%–38.1%]), superior component positioning within ±3° for the lateral distal femoral angle (88.4% [95% CI, 83.2%–92.4%] vs. 79.7% [95% CI, 68.8%–87.5%]) and for the medial proximal tibial angle (91.2% [95% CI, 86.3%–94.6%] vs. 82.6% [95% CI, 72.0%–89.8%]), and better joint line restoration (79.5% vs. 58.3% within 4 mm). Procedures required an additional 15–24 min. Complication rates were comparable between groups. For UKA revisions, outcomes were generally similar between technology‐assisted and conventional techniques, with mixed results on alignment accuracy and clinical scores.

Conclusion

Technology‐assisted revTKA achieves optimal alignment parameters and reduces the occurrence of outliers compared with conventional techniques. However, these radiographic improvements do not consistently translate into enhanced clinical outcomes or reduced complication rates. Level of Evidence Level IV.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeReoperationRobotic Surgical ProceduresHumansKnee JointKnee ProsthesisPostoperative ComplicationsRadiography

Stichwörter der Autor:innen

joint line restorationprecision accuracyrobotic‐assisted revision total knee arthroplastyrobotic‐assisted revision unicompartmental knee arthroplastytechnology

Autor:innen und Institutionen

  • Department of Clinical Orthopaedics, University of Florence, Florence, Italy.
  • Department of Orthopaedic Surgery, Sint Maartenskliniek, Nijmegen, the Netherlands.
  • Orthopedisch Centrum Oost Nederland, Orthopedic Center, Hengelo, the Netherlands.

ORCID-Profile: Matteo Innocenti, Filippo Leggieri, Simon N van Laarhoven, Tommy de Windt, Roberto Civinini, Gijs G van Hellemondt

Zitieren

APA

Innocenti, M., Leggieri, F., van Laarhoven, S. N., de Windt, T., Civinini, R., & van Hellemondt, G. G. (2025). Technology‐assisted revision knee arthroplasty reduces radiographic outliers compared with standard revision knee surgery: A systematic review. Knee Surgery, Sports Traumatology, Arthroscopy, 33(10), 3606-3620. https://doi.org/10.1002/ksa.12748

Vancouver

Innocenti M, Leggieri F, van Laarhoven SN, de Windt T, Civinini R, van Hellemondt GG. Technology‐assisted revision knee arthroplasty reduces radiographic outliers compared with standard revision knee surgery: A systematic review. Knee Surgery, Sports Traumatology, Arthroscopy. 2025;33(10):3606-3620. doi:10.1002/ksa.12748

BibTeX
@article{Innocenti2025,
  author = {Innocenti, Matteo and Leggieri, Filippo and van Laarhoven, Simon N and de Windt, Tommy and Civinini, Roberto and van Hellemondt, Gijs G},
  title = {Technology‐assisted revision knee arthroplasty reduces radiographic outliers compared with standard revision knee surgery: A systematic review},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  volume = {33},
  number = {10},
  pages = {3606--3620},
  doi = {10.1002/ksa.12748}
}
Kostenlos starten →