EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A new parameter in the era of robotic total knee arthroplasty: Coronal alignment at 90° of flexion impacts clinical outcomes

Luca Andriollo, Christos Koutserimpas, Pietro Gregori, Elvire Servien, Cécile Batailler, Sébastien Lustig

Knee Surgery, Sports Traumatology, Arthroscopy · 2025

DOI: 10.1002/ksa.12648 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025. Verfasst von Luca Andriollo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix Rousse Hospital, Hospices Civils de Lyon, Lyon North Un…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Osteoarthritis, Knee, Knee Joint. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Alignment strategies in total knee arthroplasty (TKA) have predominantly emphasized coronal alignment in extension, with minimal focus on dynamic alignment during flexion. This study aims to identify the predictors of the intraoperative robotic hip–knee–ankle angle at 90° of flexion (rHKA‐90F) and assess its clinical significance in postoperative outcomes, proposing that rHKA‐90F may be a critical factor in enhancing functional results in TKA.

Methods

A retrospective analysis was conducted on 180 patients with varus deformity undergoing robotic‐assisted TKA under the functional alignment principles. Clinical outcomes were assessed using the Knee Society Score (KSS), Forgotten Joint Score (FJS‐12) and Kujala Anterior Knee Pain Scale (AKPS) score. Predictors for final rHKA‐90F and its intraoperative changes were identified using multiple linear regression models. Initial and intraoperative robotic measurements were also analyzed.

Results

Significant predictors of the final rHKA‐90F included femoral rotation, tibial varus/valgus alignment, initial rHKA‐90F and the final robotic axis in extensions. Patients with a final rHKA‐90F ≥ 5° of varus demonstrated superior KSS function and KSS knee compared to those with a final rHKA‐90F between 0° and 4° of varus. Furthermore, patients with intraoperative changes of rHKA‐90F > 2.5° neutralization (varus reduction or with a valgus value) achieved better FJS and AKPS score.

Conclusions

This study highlights the clinical relevance of rHKA‐90F as an intraoperative tool in robotic knee arthroplasty, emphasizing the need to balance the correction of varus deformity with the maintenance of slight varus alignment in flexion. Personalized alignment strategies tailored to patient‐specific anatomy and kinematics are crucial to optimizing outcomes. There is still a need for future research on the long‐term effects of dynamic alignment. Level of Evidence Level III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresOsteoarthritis, KneeKnee JointHumansRetrospective StudiesFemaleMaleAgedMiddle AgedRange of Motion, ArticularTreatment OutcomeAged, 80 and over

Stichwörter der Autor:innen

TKAalignment in flexiondynamic HKAfunctional alignmentfunctional knee positioningknee arthroplasty

Autor:innen und Institutionen

  • Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix Rousse Hospital, Hospices Civils de Lyon, Lyon North University Hospital, Lyon, France.
  • Sezione di Chirurgia Protesica ad Indirizzo Robotico - Unità di Traumatologia Dello Sport, Ortopedia e Traumatologia, Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy.
  • Ortopedia e Traumatologia, Università Cattolica del Sacro Cuore, Rome, Italy.
  • Fondazione Policlinico Universitario Campus Bio-Medico, Roma, Italy.
  • LIBM-EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University, Lyon, France.
  • Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, Lyon, France.

Zitieren

APA

Andriollo, L., Koutserimpas, C., Gregori, P., Servien, E., Batailler, C., & Lustig, S. (2025). A new parameter in the era of robotic total knee arthroplasty: Coronal alignment at 90° of flexion impacts clinical outcomes. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12648

Vancouver

Andriollo L, Koutserimpas C, Gregori P, Servien E, Batailler C, Lustig S. A new parameter in the era of robotic total knee arthroplasty: Coronal alignment at 90° of flexion impacts clinical outcomes. Knee Surgery, Sports Traumatology, Arthroscopy. 2025. doi:10.1002/ksa.12648

BibTeX
@article{Andriollo2025,
  author = {Andriollo, Luca and Koutserimpas, Christos and Gregori, Pietro and Servien, Elvire and Batailler, Cécile and Lustig, Sébastien},
  title = {A new parameter in the era of robotic total knee arthroplasty: Coronal alignment at 90° of flexion impacts clinical outcomes},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  doi = {10.1002/ksa.12648}
}
Kostenlos starten →