EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The use of an imageless robotic system in revision of unicompartmental knee arthroplasty

Luca Andriollo, Francesco Benazzo, Virgina Cinelli, Rudy Sangaletti, Calogero Velluto, Stefano Marco Paolo Rossi iD

Knee Surgery, Sports Traumatology, Arthroscopy · 2025

DOI: 10.1002/ksa.12574 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025. Verfasst von Luca Andriollo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Sezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia Dello Sport, UOC Ortopedia e Traumatologia, Brescia, Italy. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Reoperation. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The application of robotics in revision arthroplasty particularly from unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA), is underexplored. The purpose of this study is to describe the surgical technique of an imageless robotic system used in the revision of UKA to TKA and to evaluate short‐ to mid‐term outcomes.

Methods

This prospective study includes 35 patients treated from May 2020 to July 2023. Demographic data of the patients were gathered and the reasons for needing revision surgery were assessed. All patients were clinically evaluated preoperatively and at the final follow‐up of 31.3 ± 12.1 months, using the Western Ontario and McMaster Universities Arthritis Index (WOMAC), Oxford Knee Score (OKS), Forgotten Joint Score (FJS‐12), Numerical Rating Scale (NRS) and range of motion (ROM). Additionally, a radiographic evaluation was performed, and implant survival was assessed by analyzing complications at final follow‐up.

Results

In 88.6% of the patients, a primary Posterior Stabilized (PS) or Constrained Posterior Stabilized prosthetic implant was used, with 11.4% of patients requiring a varus‐valgus constraint implant. In 71.4% of the cases, a thinnest size liner of 10 mm was used. The use of the robotic system was never aborted for any reason. At final follow‐up, the implant survival rate was 97.14%. Average OKS increased from 31.4 ± 9.4 to 41.5 ± 4.3, FJS‐12 from 47.3 ± 19.3 to 80.7 ± 8.9; WOMAC at final follow‐up was 17.8 ± 8.7, from 53.5 ± 21.3 preoperatively. Analyzing ROM, NRS and patient‐reported outcome measures, there were significant differences in each parameter between prerevision surgery and final follow‐up.

Conclusions

This study highlights that in a cohort of patients undergoing robotic‐assisted conversion from UKA to TKA, the use of an imageless procedure incorporating intraoperative bone morphing and alignment based on a functional philosophy has proven to be safe and has yielded excellent clinical and radiographic outcomes. Level of Evidence Level II, prospective cohort study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresReoperationHumansMaleFemaleProspective StudiesAgedMiddle AgedRange of Motion, ArticularKnee ProsthesisAged, 80 and over

Stichwörter der Autor:innen

TKAUKAimagelessknee arthroplastyrevisionrobotic

Autor:innen und Institutionen

  • Sezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia Dello Sport, UOC Ortopedia e Traumatologia, Brescia, Italy.
  • Università Cattolica del Sacro Cuore, Roma, Italy.
  • Artificial Intelligence Center, Alma Mater Europaea University, Vienna, Austria.
  • IUSS Istituto Universitario di Studi Superiori, Pavia, Italy.
  • Department of Life Science, Health, and Health Professions, Università degli Studi Link, Link Campus University, Roma, Italy.

ORCID-Profile: Stefano Marco Paolo Rossi

Zitieren

APA

Andriollo, L., Benazzo, F., Cinelli, V., Sangaletti, R., Velluto, C., & Rossi, S. M. P. (2025). The use of an imageless robotic system in revision of unicompartmental knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12574

Vancouver

Andriollo L, Benazzo F, Cinelli V, Sangaletti R, Velluto C, Rossi SMP. The use of an imageless robotic system in revision of unicompartmental knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy. 2025. doi:10.1002/ksa.12574

BibTeX
@article{Andriollo2025,
  author = {Andriollo, Luca and Benazzo, Francesco and Cinelli, Virgina and Sangaletti, Rudy and Velluto, Calogero and Rossi, Stefano Marco Paolo},
  title = {The use of an imageless robotic system in revision of unicompartmental knee arthroplasty},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  doi = {10.1002/ksa.12574}
}
Kostenlos starten →