EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

A flat posterior cruciate ligament reconstruction restores native knee kinematics, comparable to a double‐bundle reconstruction—A biomechanical robotic investigation

Adrian Deichsel, Florian Gellhaus, Christian Peez, Michael J Raschke, Moritz Martinovic, Elmar Herbst, Mirco Herbort, Christian Fink, Christoph Kittl

Knee Surgery, Sports Traumatology, Arthroscopy · 2025

DOI: 10.1002/ksa.12572 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025. Verfasst von Adrian Deichsel und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany. Hauptthemen laut MEDLINE: Posterior Cruciate Ligament Reconstruction, Knee Joint, Posterior Cruciate Ligament, Robotic Surgical Procedures. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgesellschaft as part of a Clinician Scientist Rotation (DFG; German Research Foundation).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To biomechanically evaluate a flat posterior cruciate ligament (PCL) reconstruction utilizing rectangular femoral bone tunnels.

Methods

Eight fresh‐frozen human knee specimens were tested in a six‐degrees‐of‐freedom robotic test setup. In each testing step, a force‐controlled test protocol was performed, including 89 N posterior tibial translation (PTT) in neutral, internal and external rotation, from 0 to 90° of flexion. After determining the native knee kinematics, the PCL was cut. Subsequently, a flat PCL reconstruction (PCLR) with a rectangular bone tunnel was performed, utilizing a quadriceps tendon autograft with a patellar bone block. After filling the bone tunnel, a single‐bundle PCLR without and with femoral interference screw fixation, as well as a double‐bundle reconstruction, was performed. Statistical analysis was performed using mixed linear models.

Results

Cutting of the PCL led to significant ( p ≤ .05) increases in PTT, from 0 to 90° of flexion, up to 10.7 mm, in comparison to the native state. After flat reconstruction and double‐bundle reconstruction, no significant difference was found between the native and reconstructed state ( p ≥ .05). The single‐bundle PCLR without interference screw showed significantly increased PTT in comparison to the native state in 30° (mean difference [MD] 3.3 mm; 95% confidence interval [CI] 1.3 – 5.2 mm; p < .001), 60° (MD 4.4 mm; 95% CI 2.5–6.4 mm; p < .001) and 90° of flexion (MD 4.0 mm; 95% CI 2.1–6.0 mm; p < .001). The single‐bundle PCLR with additional interference screw showed significantly increased PTT in comparison to the native state only in 30° (MD 1.9 mm; 95% CI 0.05–3.8 mm; p = .01).

Conclusion

Both a flat and a double‐bundle PCLR were able to restore the native knee kinematics in all tested flexion angles. A single‐bundle reconstruction was not able to fully restore native kinematics, with only small residual anteroposterior instability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Posterior Cruciate Ligament ReconstructionKnee JointPosterior Cruciate LigamentRobotic Surgical ProceduresHumansBiomechanical PhenomenaMaleFemaleMiddle AgedCadaverAgedRange of Motion, Articular

Stichwörter der Autor:innen

biomechanicsposterior cruciate ligament, PCLreconstructionrectangular

Autor:innen und Institutionen

  • Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
  • Department of Anatomy, Christian-Albrechts-University, Kiel, Germany.
  • OCM Clinic, Munich, Germany.
  • Research Unit for Orthopedic Sports Medicine and Injury Prevention (OSMI), UMIT Hall, Austria.
  • Gelenkpunkt, Sports and Joint Surgery Innsbruck, Innsbruck, Austria.

Förderung

  • Deutsche Forschungsgesellschaft as part of a Clinician Scientist Rotation (DFG; German Research Foundation)

Zitieren

APA

Deichsel, A., Gellhaus, F., Peez, C., Raschke, M. J., Martinovic, M., Herbst, E., Herbort, M., Fink, C., & Kittl, C. (2025). A flat posterior cruciate ligament reconstruction restores native knee kinematics, comparable to a double‐bundle reconstruction—A biomechanical robotic investigation. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12572

Vancouver

Deichsel A, Gellhaus F, Peez C, Raschke MJ, Martinovic M, Herbst E, et al. A flat posterior cruciate ligament reconstruction restores native knee kinematics, comparable to a double‐bundle reconstruction—A biomechanical robotic investigation. Knee Surgery, Sports Traumatology, Arthroscopy. 2025. doi:10.1002/ksa.12572

BibTeX
@article{Deichsel2025,
  author = {Deichsel, Adrian and Gellhaus, Florian and Peez, Christian and Raschke, Michael J and Martinovic, Moritz and Herbst, Elmar and Herbort, Mirco and Fink, Christian and Kittl, Christoph},
  title = {A flat posterior cruciate ligament reconstruction restores native knee kinematics, comparable to a double‐bundle reconstruction—A biomechanical robotic investigation},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  doi = {10.1002/ksa.12572}
}
Kostenlos starten →