Cut‐off value for the posterior tibial slope indicating the risk for retear of the anterior cruciate ligament
Knee Surgery, Sports Traumatology, Arthroscopy · 2025
DOI: 10.1002/ksa.12552 ↗Kurz gefasst
Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025. Verfasst von Anel Dracic und 4 weiteren Autor:innen. Beteiligte Einrichtung: Sportsclinic Hellersen, Lüdenscheid, Germany. Hauptthemen laut MEDLINE: Tibia, Anterior Cruciate Ligament Reconstruction, Anterior Cruciate Ligament Injuries. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 48 Literaturangaben.
Abstract (Originalsprache)
Purpose
The significance of the posterior tibial slope (PTS) has increasingly come into focus in anterior cruciate ligament (ACL) reconstruction being a risk factor for ACL graft failure. Nevertheless, inconsistent data on the critical value of the PTS exist. The purpose of this study was to define a cut‐off value for the PTS in ACL surgery.
Methods
In a retrospective cohort study, 350 revision ACL reconstructions (ACL‐RR) with a failed ACL hamstring graft and 350 primary ACL reconstructions (ACL‐R) were matched according to age, gender, concomitant injuries and graft characteristics and compared to a healthy control group. Using the proximal anatomic axis, lateral knee radiographs were evaluated for the PTS, interrater reliability was defined, ROC curves, Fischer's exact test and Baptista–Pike method were applied to define specificity and the odds ratio for a critical PTS value.
Results
Radiographic evaluation proved excellent interrater reliability (intraclass correlation coefficient 0.969). Evaluation of the PTS revealed 10.0 ± 2.2 (5–15) degrees in the ACL‐RR group, 7.8 ± 1.8 (4.2–13) degrees in the ACL‐R group and 6.6 ± 1.9 (3.6–12) degrees in the control group with significant differences between the groups ( p < 0.001). A PTS value of 10.1 degrees proved a specificity of 98% for the prediction of an ACL graft failure and indicated an 11‐fold risk for a retear of the ACL.
Conclusion
A PTS exceeding 10.1 degrees carries an 11‐fold risk for ACL graft failure and, therefore, should be considered in ACL reconstruction. These findings might serve as a cut‐off value for the indication of a slope‐reducing high tibial osteotomy in ACL surgery. Level of Evidence Level III.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sportsclinic Hellersen, Lüdenscheid, Germany.
- Orthopädische Klinik Volmarstein, Wetter, Germany.
- Department of Orthopaedics, Trauma and Reconstructive Surgery, St. Marien Hospital Mülheim, Contilia Gruppe, Mülheim, Germany.
- Orthopaedics and Trauma Surgery, University of Duisburg-Essen, Essen, Germany.
Zitieren
APA
Dracic, A., Zeravica, D., Zovko, I., Jäger, M., & Beck, S. (2025). Cut‐off value for the posterior tibial slope indicating the risk for retear of the anterior cruciate ligament. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12552
Vancouver
Dracic A, Zeravica D, Zovko I, Jäger M, Beck S. Cut‐off value for the posterior tibial slope indicating the risk for retear of the anterior cruciate ligament. Knee Surgery, Sports Traumatology, Arthroscopy. 2025. doi:10.1002/ksa.12552
BibTeX
@article{Dracic2025,
author = {Dracic, Anel and Zeravica, Domagoj and Zovko, Ivica and Jäger, Marcus and Beck, Sascha},
title = {Cut‐off value for the posterior tibial slope indicating the risk for retear of the anterior cruciate ligament},
journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
year = {2025},
doi = {10.1002/ksa.12552}
}
EUVIMED