Validation of a software‐based torsional measurement method of the lower limb: A retrospective study
Knee Surgery, Sports Traumatology, Arthroscopy · 2025
DOI: 10.1002/ksa.12509 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025. Verfasst von Leonard Grünwald und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Traumatology and Reconstructive Surgery, BG Trauma Center Tübingen, Eberhard Karls University Tübingen, Tübingen, Germany. Hauptthemen laut MEDLINE: Tibia, Software, Tomography, X-Ray Computed, Femur. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: None.
Abstract (Originalsprache)
Purpose
The aim of this study was to evaluate a software‐based measurement tool of computed tomography imaging to assess torsional alignment of the lower limb—usually used for patients with posttraumatic deformities and patellofemoral issues—and compare these measurements with manual measurements of two experienced raters.
Methods
This study was a retrospective analysis of 58 lower limbs (47 patients, 20 men and 27 women) aged between 19 and 97 years. Inclusion criteria were the clinical indication for torsion measurement of the lower limb. Legs with incomplete imaging and age less than 18 years were excluded. Femoral and tibial torsion were measured separately. Torsional alignment was assessed software‐based at two time points by two raters. Rater one additionally assessed manual‐based measurement at two time points. The software used was mediCAD 3D Knee Version 2.5.33 (Hectec). Subsequently, intra‐ and inter‐rater reliability was calculated using the intraclass correlation coefficient (ICC). Validity testing was performed by means of precision, concordance correlation coefficient according to Lin (ccc) and Pearson correlation coefficient.
Results
High intra‐rater reliability for software‐based as well as manual‐based evaluation of torsional alignment was found for the tibia as well as the femur (ICC ranging between 0.870 and 0.993). Inter‐rater reliability also showed highly significant results of both manual and software‐based measurements (ICC ranging between 0.851 and 0.993). For almost all comparisons (except the tibia left), software‐based measurements showed higher ICC scores above 0.9, and, therefore, classified as ‘excellent reliability’. For validity testing, correlation coefficients and precision showed very good correspondence of the measurements (all values > 0.9), without systematic deviations.
Conclusions
Software‐based measurement of torsional alignment according to the measurement method developed by H.‐A. Waidelich proved to be a reliable and valid technique. Especially for inexperienced surgeons, software‐based measurement, therefore, might improve confidence in reliable medical decisions in diagnostics and treatment. Level of Evidence Level III.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Traumatology and Reconstructive Surgery, BG Trauma Center Tübingen, Eberhard Karls University Tübingen, Tübingen, Germany.
- Osteotomie Komitee der Deutschen Kniegesellschaft, München, Germany.
- Yokohama City University School of Medicine, Yokohama, Japan.
- Diakonie Klinikum GmbH Jung-Stilling Krankenhaus Siegen, Siegen, Germany.
- Klinikverbund Südwest, Kliniken Sindelfingen, Sindelfingen, Germany.
Förderung
- None
Zitieren
APA
Grünwald, L., Nejima, S., Histing, T., Schröter, S., & Hagedorn, P. (2025). Validation of a software‐based torsional measurement method of the lower limb: A retrospective study. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12509
Vancouver
Grünwald L, Nejima S, Histing T, Schröter S, Hagedorn P. Validation of a software‐based torsional measurement method of the lower limb: A retrospective study. Knee Surgery, Sports Traumatology, Arthroscopy. 2025. doi:10.1002/ksa.12509
BibTeX
@article{Grnwald2025,
author = {Grünwald, Leonard and Nejima, Shuntaro and Histing, Tina and Schröter, Steffen and Hagedorn, Peter},
title = {Validation of a software‐based torsional measurement method of the lower limb: A retrospective study},
journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
year = {2025},
doi = {10.1002/ksa.12509}
}
EUVIMED