EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High accuracy of component positioning and restoration of lower limb alignment using robotic medial unicompartmental knee arthroplasty

Emanuele Diquattro, Jonathan Lettner, Marco Adriani, Robert Prill, Mikhail Salzmann, Roland Becker

Knee Surgery, Sports Traumatology, Arthroscopy · 2025

DOI: 10.1002/ksa.12484 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025. Verfasst von Emanuele Diquattro und 5 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedic-Traumatology and Prosthetic Surgery and Revisions of Hip and Knee Implants, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Osteoarthritis, Knee, Bone Malalignment. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: None.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Unicondylar arthroplasty was performed using robotic medial unicompartmental knee arthroplasty (R‐mUKA) and gap‐balancing instrumentation. Our hypothesis was that robotic unicondylar knee arthroplasty accurately restores component positioning and lower limb alignment when compared to preoperative planning with actual implantation throughout the range of knee motion due to proper knee balancing.

Methods

Data were collected prospectively and were analysed for patients undergoing R‐mUKA. A cemented UKA was implanted using the MAKO® robotic system. Lower limb alignment at 0°, 30°, 45°, 60° and 90° of flexion was recorded of the native knee, with the trial components in place and finally after component implantation. A spacer according to the femorotibial gap was introduced and the alignment was measured. The position of the final component was planned based on three‐dimensional computed tomography images before making the bone cuts. The positioning of the femoral and tibial components was analysed in all three planes.

Results

A total of 52 patients were included (mean age 66.3 ± 6.7 years; 34 males, 18 females). The difference in femoral component position after planning and final implantation was 0.04° ± 0.58° more valgus in the coronal plane ( p = 0.326) and 0.6° ± 1.4° more flexion relative to the sagittal plane ( p = 0.034). The tibial component was placed in the coronal plane in 0.3° ± 0.8° of more varus ( p = 0.113) and in the sagittal plane in 0.6° ± 1.2° of more posterior tibial slope ( p = 0.001). Lower limb alignment of the native knee in extension was 5.8° ± 2.6° of varus and changed to 3° ± 2.1° varus after UKA ( p ≤ 0.01).

Conclusion

R‐mUKA helps to achieve the target of alignment and component position without any significant differences to the planning. Ligament balancing causes non‐significant changes in component position. It allows optimal component position even for off‐the‐shelf implants respecting the patient's specific anatomy. Level of Evidence Level II.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresOsteoarthritis, KneeBone MalalignmentHumansMaleFemaleAgedMiddle AgedProspective StudiesKnee ProsthesisRange of Motion, ArticularKnee JointLower ExtremityTomography, X-Ray Computed

Stichwörter der Autor:innen

MAKOaccuracyligament tensionroboticsunicondylar knee arthroplasty

Autor:innen und Institutionen

  • Orthopaedic-Traumatology and Prosthetic Surgery and Revisions of Hip and Knee Implants, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.
  • Center of Orthopaedics and Traumatology, University Hospital Brandenburg an der Havel, Brandenburg, Germany.
  • Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia, Brescia, Italy.
  • Faculty of Health Sciences, Potsdam, Germany.

Förderung

  • None

Zitieren

APA

Diquattro, E., Lettner, J., Adriani, M., Prill, R., Salzmann, M., & Becker, R. (2025). High accuracy of component positioning and restoration of lower limb alignment using robotic medial unicompartmental knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12484

Vancouver

Diquattro E, Lettner J, Adriani M, Prill R, Salzmann M, Becker R. High accuracy of component positioning and restoration of lower limb alignment using robotic medial unicompartmental knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy. 2025. doi:10.1002/ksa.12484

BibTeX
@article{Diquattro2025,
  author = {Diquattro, Emanuele and Lettner, Jonathan and Adriani, Marco and Prill, Robert and Salzmann, Mikhail and Becker, Roland},
  title = {High accuracy of component positioning and restoration of lower limb alignment using robotic medial unicompartmental knee arthroplasty},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  doi = {10.1002/ksa.12484}
}
Kostenlos starten →