EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Cobra sign: A marker for overestimation of tendon retraction in proximal semimembranosus tendon avulsion

Nicolas Lefèvre, Mohamad K Moussa, Ahmad Chahal, Alain Meyer, Olivier Grimaud, Zeinab M Khalaf, Ali Alayane, Yoann Bohu, Alexandre Hardy

Knee Surgery, Sports Traumatology, Arthroscopy · 2025

DOI: 10.1002/ksa.12437 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025. Verfasst von Nicolas Lefèvre und 8 weiteren Autor:innen. Beteiligte Einrichtung: Clinique du Sport, Paris, France. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Tendon Injuries, Hamstring Tendons. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: None.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To introduce a new magnetic resonance imaging (MRI) sign, termed the Cobra sign, and identify its diagnostic metrics. The secondary aim was to demonstrate that this sign can be a source of false evaluation of tendon retraction in patients with proximal hamstring avulsion injury.

Method

This retrospective cohort study targeted patients surgically treated for proximal hamstring avulsion injury from January 2019 to June 2023. The MRI Cobra sign was defined as a wavy curved T2‐hypointense band with the free end folding distally over itself, resembling a cobra head. The primary outcome measure was the characterization of the Cobra sign in patients with proximal hamstring avulsion injury. The secondary outcome was the association of this sign with tendon retraction. The study included 81 proximal hamstring avulsion injury patients (mean age of 45.7, SD = 13.9), with 41 (50.6%) complete avulsions, 33 semimembranosus, and 7 conjoint tendons.

Results

The MRI Cobra sign was found in 25 patients (17 semimembranosus and 8 complete). It was confirmed surgically only in semimembranosus cases. It demonstrated 51.5% sensitivity and 83.3% specificity for isolated semimembranosus avulsions, with a significant positive likelihood ratio of 3.0. MRI retraction was 10.05 cm (±3.0), reducing to 7.9 cm (±2.5) on surgical measurement (mean difference = 2.0 cm, p < 0.001). The regression analysis confirmed MRI retraction's influence on the Cobra sign, with a 1.4 odds increase per unit ( p < 0.001). In linear regression analysis, each unit increase in MRI retraction corresponded to a 79% increase in surgical retraction (coefficient 0.7, t = 11.1, p < 0.001).

Conclusion

The Cobra sign demonstrated acceptable diagnostic accuracy for isolated semimembranosus avulsion, with a high specificity of 83.3%, a low sensitivity of 51.5%, and a positive likelihood ratio of 3.0. The presence of the Cobra sign indicates an overestimated MRI retraction by approximately 21%. Level of Evidence Level III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingTendon InjuriesHamstring TendonsHumansRetrospective StudiesMaleFemaleMiddle AgedAdultSensitivity and Specificity

Stichwörter der Autor:innen

MRI retractionMRI signhamstring avulsionsemimembranosussurgical retraction

Autor:innen und Institutionen

  • Clinique du Sport, Paris, France.
  • Department of Orthopedic Surgery, Group Hospitalier Sélestat Obernai, Séléstat, Alsace, France.
  • Department of Radiology, Hôpital Saint Camille, Bry-sur-Marne, France.

Förderung

  • None

Zitieren

APA

Lefèvre, N., Moussa, M. K., Chahal, A., Meyer, A., Grimaud, O., Khalaf, Z. M., Alayane, A., Bohu, Y., & Hardy, A. (2025). The Cobra sign: A marker for overestimation of tendon retraction in proximal semimembranosus tendon avulsion. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12437

Vancouver

Lefèvre N, Moussa MK, Chahal A, Meyer A, Grimaud O, Khalaf ZM, et al. The Cobra sign: A marker for overestimation of tendon retraction in proximal semimembranosus tendon avulsion. Knee Surgery, Sports Traumatology, Arthroscopy. 2025. doi:10.1002/ksa.12437

BibTeX
@article{Lefvre2025,
  author = {Lefèvre, Nicolas and Moussa, Mohamad K and Chahal, Ahmad and Meyer, Alain and Grimaud, Olivier and Khalaf, Zeinab M and Alayane, Ali and Bohu, Yoann and Hardy, Alexandre},
  title = {The Cobra sign: A marker for overestimation of tendon retraction in proximal semimembranosus tendon avulsion},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  doi = {10.1002/ksa.12437}
}
Kostenlos starten →