Artificial intelligence‐based assessment of leg axis parameters shows excellent agreement with human raters: A systematic review and meta‐analysis

KI-basierte Beurteilung von Beinachsenparametern zeigt exzellente Übereinstimmung mit menschlichen Beurteilenden: systematische Übersicht und Metaanalyse

Mikhail Salzmann, Hakam Hassan Tarek, Robert Prill, Roland Becker, Andreas G Schreyer, Robert Hable, Marko Ostojic, Nikolai Ramadanov

Knee Surgery, Sports Traumatology, Arthroscopy · 2025-01 · 33 (1) · 177-190

DOI: 10.1002/ksa.12362 ↗

Auf einen Blick

13 Studien mit 3.192 Patient:innen zeigten eine exzellente Übereinstimmung zwischen KI und menschlichen Beurteilenden bei Beinachsenmessungen auf Langbeinröntgen. Die KI war beim Auslesen etwa 3 min schneller.

Fragestellung

Wie zuverlässig und anwendbar ist eine KI-basierte Analyse von Beinachsenparametern im Vergleich zu menschlichen Beurteilenden?

Methode

Systematische Übersicht und Metaanalyse; Suche in PubMed, Epistemonikos und Web of Science bis 24. Februar 2024; frequentistische Metaanalyse mit Common-Effect-/Random-Effects-Modell.

Ergebnisse

13 Studien mit 3.192 Patient:innen. HKA, mLDFA, mMPTA und JLCA zeigten exzellente Übereinstimmung zwischen KI und menschlichen Beurteilenden. Die KI war beim Lesen stehender Langbein-AP-Röntgenbilder etwa 3 min schneller.

Schlussfolgerung der Autor:innen

Die KI-basierte Beurteilung von Beinachsenparametern ist laut den Autor:innen effizient, genau und zeitsparend. Die Qualität scheint durch Implantate oder pathologische Befunde nicht beeinträchtigt zu sein.

Kernaussagen

  • Exzellente Übereinstimmung bei HKA, mLDFA, mMPTA und JLCA
  • KI etwa 3 min schneller als menschliche Beurteilende
  • Keine Beeinträchtigung durch Implantate oder pathologische Bedingungen berichtet

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Systematische Übersicht in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 21.07.2024. Verfasst von Mikhail Salzmann und 7 weiteren Autor:innen. Beteiligte Einrichtung: Center of Orthopaedics and Traumatology, Brandenburg Medical School, University Hospital Brandenburg an der Havel, Brandenburg an der Havel, Germany. Hauptthemen laut MEDLINE: Artificial Intelligence. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: None.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim of this study was to conduct a systematic review and meta‐analysis on the reliability and applicability of artificial intelligence (AI)‐based analysis of leg axis parameters. We hypothesized that AI‐based leg axis measurements would be less time‐consuming and as accurate as those performed by human raters.

Methods

The study protocol was registered with the International Prospective Register of Systematic Reviews (PROSPERO). PubMed, Epistemonikos, and Web of Science were searched up to 24 February 2024, using a BOOLEAN search strategy. Titles and abstracts of identified records were screened through a stepwise process. Data extraction and quality assessment of the included papers were followed by a frequentist meta‐analysis employing a common effect/random effects model with inverse variance and the Sidik–Jonkman heterogeneity estimator.

Results

A total of 13 studies encompassing 3192 patients were included in this meta‐analysis. All studies compared AI‐based leg axis measurements on long‐leg radiographs (LLR) with those performed by human raters. The parameters hip knee ankle angle (HKA), mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), and joint‐line convergence angle (JLCA) showed excellent agreement between AI and human raters. The AI system was approximately 3 min faster in reading standing long‐leg anteroposterior radiographs (LLRs) compared with human raters.

Conclusion

AI‐based assessment of leg axis parameters is an efficient, accurate, and time‐saving procedure. The quality of AI‐based assessment of the investigated parameters does not appear to be affected by the presence of implants or pathological conditions. Level of Evidence Level I.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial IntelligenceHumansReproducibility of ResultsRadiographyKnee JointFemurTibiaHip JointLeg

Stichwörter der Autor:innen

AIalignment measurementartificial intelligenceautomated measurementdeep learningleg axis

Autor:innen und Institutionen

  • Center of Orthopaedics and Traumatology, Brandenburg Medical School, University Hospital Brandenburg an der Havel, Brandenburg an der Havel, Germany.
  • Faculty of Health Science Brandenburg, Brandenburg Medical School Theodor Fontane, Brandenburg an der Havel, Germany.
  • Institute for Diagnostic and Interventional Radiology, Brandenburg Medical School Theodor Fontane, Brandenburg an der Havel, Germany.
  • Faculty of Applied Computer Science, Deggendorf Institute of Technology, Deggendorf, Germany.
  • Department of Orthopedics, University Hospital Mostar, Mostar, Bosnia and Herzegovina.

Förderung

  • None

Zitieren

APA

Salzmann, M., Hassan Tarek, H., Prill, R., Becker, R., Schreyer, A. G., Hable, R., Ostojic, M., & Ramadanov, N. (2025). Artificial intelligence‐based assessment of leg axis parameters shows excellent agreement with human raters: A systematic review and meta‐analysis. Knee Surgery, Sports Traumatology, Arthroscopy, 33(1), 177-190. https://doi.org/10.1002/ksa.12362

Vancouver

Salzmann M, Hassan Tarek H, Prill R, Becker R, Schreyer AG, Hable R, et al. Artificial intelligence‐based assessment of leg axis parameters shows excellent agreement with human raters: A systematic review and meta‐analysis. Knee Surgery, Sports Traumatology, Arthroscopy. 2025;33(1):177-190. doi:10.1002/ksa.12362

BibTeX
@article{Salzmann2025,
  author = {Salzmann, Mikhail and Hassan Tarek, Hakam and Prill, Robert and Becker, Roland and Schreyer, Andreas G and Hable, Robert and Ostojic, Marko and Ramadanov, Nikolai},
  title = {Artificial intelligence‐based assessment of leg axis parameters shows excellent agreement with human raters: A systematic review and meta‐analysis},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  volume = {33},
  number = {1},
  pages = {177--190},
  doi = {10.1002/ksa.12362}
}
Kostenlos starten →