Vergleichsstudie in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2024. Verfasst von Ryan Cheng und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York, USA. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Polyethylene, Knee Prosthesis. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: None.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this study was to examine the effects of intraoperative technology use on the rate of using polyethylene liners 15 mm or greater during primary total knee arthroplasty (TKA).

Methods

There were 103,295 implants from 16,386 primary unilateral TKAs performed on 14,253 patients at a single institution between 1 January 2018, and 30 June 2022, included in the current study. Robotic assistance and navigation guidance were used in 1274 (8%) and 8345 (51%) procedures, respectively. The remaining 6767 TKAs (41%) were performed manually. Polyethylene liners were manually identified and further subcategorised by implant thickness. Patients who underwent robotic‐assisted TKA were younger ( p < 0.001) and more likely to be male ( p < 0.001) compared to patients who underwent navigation‐guided or manual TKAs.

Results

Average polyethylene liner thickness was similar between groups (10.5 ± 1.5 mm for robotic‐assisted TKAs, 10.9 ± 1.8 mm for navigation‐guided TKAs and 10.8 ± 1.8 mm for manual TKAs). The proportions of polyethylene liners 15 mm or greater used were 4.9%, 3.8% and 1.9% for navigation‐guided, manual and robotic‐assisted procedures, respectively ( p < 0.001). Multivariate regression analyses demonstrated that navigation‐guided (odds ratio [OR]: 2.6, 95% confidence Interval [CI]: [1.75–4.07], p < 0.001) and manual (OR: 2.0, 95% CI: [1.34–3.20], p = 0.001) procedures were associated with an increased use of polyethylene liners 15 mm or greater.

Conclusion

Robotic‐assisted TKA was associated with a lower proportion of polyethylene liners 15 mm or greater used compared to navigation‐guided and manual TKA. These findings suggest that robotic assistance can reduce human error via a more precise cutting system, limit over‐resection of the tibia and flexion‐extension gap mismatch and ultimately allow for more appropriately sized implants. Level of Evidence Level III, retrospective cohort study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresPolyethyleneKnee ProsthesisSurgery, Computer-AssistedHumansMaleAgedFemaleMiddle AgedRetrospective StudiesProsthesis Design

Stichwörter der Autor:innen

bony resectionintraoperative technologypolyethylene linersprimary total knee arthroplastyrobotics

Substanzen

Polyethylene

Autor:innen und Institutionen

  • Department of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, New York, USA.

Förderung

  • None

Zitieren

APA

Cheng, R., Kim, B., Taylor, W. L., Westrich, G. H., & Shen, T. S. (2024). Robotic‐assisted total knee arthroplasty is associated with the use of thinner polyethylene liners compared to navigation‐guided and manual techniques. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12228

Vancouver

Cheng R, Kim B, Taylor WL, Westrich GH, Shen TS. Robotic‐assisted total knee arthroplasty is associated with the use of thinner polyethylene liners compared to navigation‐guided and manual techniques. Knee Surgery, Sports Traumatology, Arthroscopy. 2024. doi:10.1002/ksa.12228

BibTeX
@article{Cheng2024,
  author = {Cheng, Ryan and Kim, Billy and Taylor, Walter L and Westrich, Geoffrey H and Shen, Tony S},
  title = {Robotic‐assisted total knee arthroplasty is associated with the use of thinner polyethylene liners compared to navigation‐guided and manual techniques},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2024},
  doi = {10.1002/ksa.12228}
}
Kostenlos starten →