EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Microporous titanium and hydroxyapatite improve fixation of the tibial wall in unicompartmental knee replacement

Azmi Rahman, Gabrielle Omoregie, Stephen Mellon, David W Murray

Knee Surgery, Sports Traumatology, Arthroscopy · 2024

DOI: 10.1002/ksa.12092 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2024. Verfasst von Azmi Rahman und 3 weiteren Autor:innen. Beteiligte Einrichtung: Oxford Orthopaedic Engineering Centre, Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences, Botnar Research Centre, Unive…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Osteoarthritis, Knee. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: None.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Cementless Oxford unicompartmental knee replacement (OUKR) is associated with less pain than cemented OUKR 5 years postoperatively. This may be due to improved fixation at the tibial wall, which transmits tension and reduces stress in the bone below the tibial component. This study compares tibial wall fixation with three different types of fixation: cemented, cementless with hydroxyapatite (HA) and cementless with a microporous titanium coat and HA (HA + MPC).

Methods

Three consecutive cohorts were identified ( n = 221 cemented in 2005–2007, n = 118 HA in 2014–2015, n = 125 HA + MPC in 2016–2017). Analysis was performed on anterior–posterior radiographs aligned on the tibial component taken 1–2 years postoperatively. Aligned radiographs are needed to see narrow radiolucencies adjacent to the wall. Alignment was assessed with rotation ratio (RR = wall width/internal wall height). Perfect RR is 0.3, and a maximum threshold of 0.5 was used. Quality of fixation to the wall was assessed with fixation ratio (FR = bone wall contact height/total wall height). Notable radiographic features at the tibial wall were also recorded.

Results

A total of 33 knees with cement, 37 knees with cementless with HA and 57 knees cementless with HA + MPC had adequately aligned radiographs. Fixation was significantly better with HA compared with cement (55% vs. 25%, p = 0.0016). The microporous coat further improved fixation (81% vs. 55%, p < 0.0001). FR > 80% was achieved in 3% of the cemented implants, 32% of HA and 68% of HA + MPC. In cementless cohorts, features suggestive of a layer of bone that had delaminated from the wall were seen in 8 (22%) HA and 3 (5%) HA + MPC knees.

Conclusion

Radiographic tibial wall fixation in OUKR is poor with cement. It improves with an HA coating and improves further with an intermediary MPC. Improved tibial wall fixation may explain the lower levels of pain observed with cementless rather than cemented fixation described in the literature, but further clinical correlation is needed. Level of Evidence Level III, retrospective cohort study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeHumansTitaniumDurapatiteRetrospective StudiesTreatment OutcomeProsthesis DesignBone CementsPainProsthesis Failure

Stichwörter der Autor:innen

arthroplastycementedcementlesskneeknee replacementorthopaedic fixation devicespainreplacementunicompartmental

Substanzen

TitaniumDurapatiteBone Cements

Autor:innen und Institutionen

  • Oxford Orthopaedic Engineering Centre, Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences, Botnar Research Centre, University of Oxford, Oxford, UK.
  • Indiana University School of Medicine, Indianapolis, Indiana, USA.
  • Nuffield Orthopaedic Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.

Förderung

  • None

Zitieren

APA

Rahman, A., Omoregie, G., Mellon, S., & Murray, D. W. (2024). Microporous titanium and hydroxyapatite improve fixation of the tibial wall in unicompartmental knee replacement. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12092

Vancouver

Rahman A, Omoregie G, Mellon S, Murray DW. Microporous titanium and hydroxyapatite improve fixation of the tibial wall in unicompartmental knee replacement. Knee Surgery, Sports Traumatology, Arthroscopy. 2024. doi:10.1002/ksa.12092

BibTeX
@article{Rahman2024,
  author = {Rahman, Azmi and Omoregie, Gabrielle and Mellon, Stephen and Murray, David W},
  title = {Microporous titanium and hydroxyapatite improve fixation of the tibial wall in unicompartmental knee replacement},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2024},
  doi = {10.1002/ksa.12092}
}
Kostenlos starten →