EUVIMEDEUVIMED entdecken
Crossref

Efficacy of all‐inside devices in reducing gap and step‐off in knee extension for ramp lesion repair: A cadaveric study

Jiro Kato, Hiroaki Fukushima, Shunta Hanaki, Yusuke Kawanishi, Makoto Kobayashi, Kyohei Ota, Masato Yoshida, Tetsuya Takenaga, Yohei Kawaguchi, Gen Kuroyanagi, Hiroaki Sakai, Hideki Murakami und 1 weitere

Knee Surgery, Sports Traumatology, Arthroscopy · 2024

DOI: 10.1002/ksa.12034 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2024. Verfasst von Jiro Kato und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Nagoya City University Graduate School of Medical Sciences, Nagoya City, Aichi, Japan. Hauptthemen laut MEDLINE: Menisci, Tibial, Anterior Cruciate Ligament Injuries. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: None.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim of this study is to assess the dynamics of the tear site of meniscal ramp lesions, particularly considering knee flexion angles, and validate anchor fixation using an all‐inside device.

Methods

Eight Thiel‐embalmed paired cadaveric knees with their whole bodies were used in this study. The ramp lesions were created arthroscopically, and ramp lesion dynamics were evaluated by gradually extending the knee from 90° of knee flexion. Changes in the gap and step‐off (0: no step‐off; 1: cross‐sectional overlap exists; and 2: tibial articular surface exposed) were evaluated at 90°, 60°, 30°, and 10° of knee flexion. After dynamic evaluation, all‐inside repairs of the ramp lesions using all‐inside devices were conducted. Dissection was performed to confirm the position of anchor fixation.

Results

As the knee was extended, the gap significantly decreased at all knee flexion angles. Similarly, the step‐off grade decreased as the knee was extended, and the step‐off completely disappeared in all cases when the knee was extended from 30° to 10°. The average knee flexion angle at which the gap and step‐off completely disappeared was 22.5°. After suturing the ramp lesion, arthroscopic evaluation showed that the gap had disappeared and the step‐off had been repaired in all cases. Anchor fixation locations were not found within the joint but were fixed to the semimembranosus tendon or its surrounding articular capsule. Overall, 31% (5/16) anchors were fixed to the attachment site of the semimembranosus tendon, whereas the remaining were fixed to the articular capsule, located peripherally to the semimembranosus tendon.

Conclusion

Suturing with an all‐inside device for ramp lesions is a good option, and the repair in knee extension was found to be reasonable, considering the dynamics of ramp lesions in this study. Level of Evidence Level IV.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Menisci, TibialAnterior Cruciate Ligament InjuriesHumansCross-Sectional StudiesKnee JointKneeCadaver

Stichwörter der Autor:innen

all-inside deviceanterior cruciate ligamentmeniscusramp lesion

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Nagoya City University Graduate School of Medical Sciences, Nagoya City, Aichi, Japan.
  • Department of Orthopedic Surgery, Ogaki Municipal Hospital, Ogaki City, Gifu, Japan.
  • Department of Orthopedic Surgery, Nagoya City University Midori Municipal Hospital, Nagoya City, Aichi, Japan.

Förderung

  • None

Zitieren

APA

Kato, J., Fukushima, H., Hanaki, S., Kawanishi, Y., Kobayashi, M., Ota, K., Yoshida, M., Takenaga, T., Kawaguchi, Y., Kuroyanagi, G., Sakai, H., Murakami, H., & Nozaki, M. (2024). Efficacy of all‐inside devices in reducing gap and step‐off in knee extension for ramp lesion repair: A cadaveric study. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12034

Vancouver

Kato J, Fukushima H, Hanaki S, Kawanishi Y, Kobayashi M, Ota K, et al. Efficacy of all‐inside devices in reducing gap and step‐off in knee extension for ramp lesion repair: A cadaveric study. Knee Surgery, Sports Traumatology, Arthroscopy. 2024. doi:10.1002/ksa.12034

BibTeX
@article{Kato2024,
  author = {Kato, Jiro and Fukushima, Hiroaki and Hanaki, Shunta and Kawanishi, Yusuke and Kobayashi, Makoto and Ota, Kyohei and Yoshida, Masato and Takenaga, Tetsuya and Kawaguchi, Yohei and Kuroyanagi, Gen and Sakai, Hiroaki and Murakami, Hideki and Nozaki, Masahiro},
  title = {Efficacy of all‐inside devices in reducing gap and step‐off in knee extension for ramp lesion repair: A cadaveric study},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2024},
  doi = {10.1002/ksa.12034}
}
Kostenlos starten →