Contrast‐Enhanced Ultrasound for Target Localization Before Ultrasound‐Guided Local Injection in Cesarean Scar Pregnancy
Journal of Ultrasound in Medicine · 31.10.2026
DOI: 10.1002/jum.70534 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Ultrasound in Medicine, online erschienen am 31.10.2026. Verfasst von Xuan Liu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound Medicine, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China. Die Arbeit nennt 19 Literaturangaben. Gefördert von: The Key New Technology Project of the Second Affiliated Hospital of Xi'an Jiaotong University.
Abstract (Originalsprache)
Objectives
To evaluate the role of contrast‐enhanced ultrasound (CEUS) in preprocedural target localization for cesarean scar pregnancy (CSP) and to assess the outcomes of ultrasound‐guided local injection.
Methods
This retrospective study included 31 patients with CSP who underwent CEUS prior to ultrasound‐guided local injection. CEUS was used to identify the hypervascular implantation site. Methotrexate (MTX) (50 mg) was administered locally into the gestational sac, followed by targeted injection toward the implantation site. Serum β‐human chorionic gonadotropin (β‐hCG) levels and ultrasound findings were monitored during follow‐up. Initial treatment success was defined as a satisfactory decline in β‐hCG levels after a single injection without additional MTX.
Results
CEUS demonstrated earlier enhancement and higher peak intensity at the implantation site than in the surrounding tissues (all p < .001). The hypervascular implantation region delineated by CEUS was significantly larger than that detected by color Doppler imaging ( p < .001). Initial treatment success was achieved in 26 of 31 patients (83.87%). The mean time to β‐hCG resolution after tissue removal was 21.78 ± 6.96 days. A major complication occurred in 1 patient (3.23%), who required surgical intervention due to severe bleeding.
Conclusions
CEUS improves visualization of the hypervascular implantation site and may facilitate target localization before ultrasound‐guided local injection. This approach appears feasible and relatively safe for the management of selected CSP patients.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound Medicine, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
ORCID-Profile: Xuan Liu, Shanshan Yu
Förderung
- The Key New Technology Project of the Second Affiliated Hospital of Xi'an Jiaotong University
Zitieren
APA
Liu, X., Chen, K., Qu, H., He, X., Ma, M., Xu, J., Feng, X., Wang, J., Jiang, J., & Yu, S. (2026). Contrast‐Enhanced Ultrasound for Target Localization Before Ultrasound‐Guided Local Injection in Cesarean Scar Pregnancy. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.70534
Vancouver
Liu X, Chen K, Qu H, He X, Ma M, Xu J, et al. Contrast‐Enhanced Ultrasound for Target Localization Before Ultrasound‐Guided Local Injection in Cesarean Scar Pregnancy. Journal of Ultrasound in Medicine. 2026. doi:10.1002/jum.70534
BibTeX
@article{Liu2026,
author = {Liu, Xuan and Chen, Ke and Qu, Huan and He, Xin and Ma, Miaoyan and Xu, Jinzhi and Feng, Xueshuo and Wang, Juan and Jiang, Jue and Yu, Shanshan},
title = {Contrast‐Enhanced Ultrasound for Target Localization Before Ultrasound‐Guided Local Injection in Cesarean Scar Pregnancy},
journal = {Journal of Ultrasound in Medicine},
year = {2026},
doi = {10.1002/jum.70534}
}
EUVIMED