EUVIMEDEUVIMED entdecken
Crossref

Super‐Resolution Ultrasound for Lymph Node Evaluation: Diagnostic Value of Static Time‐Point Parameters Versus Dynamic Temporal Changes

Qing Xie iD, Ruixue Cui iD, Zhendan Zhao, Ming Li iD, Yuehua Gao, Huawei Zhang iD

Journal of Ultrasound in Medicine · 02.11.2026

DOI: 10.1002/jum.70497 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Ultrasound in Medicine, online erschienen am 02.11.2026. Verfasst von Qing Xie und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China. Die Arbeit nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate quantitative super‐resolution ultrasound (SRUS) parameters (static central‐to‐peripheral ratios and dynamic temporal changes) for differentiating benign and metastatic lymph nodes, and to compare the performance of corresponding predictive models.

Methods

A prospective study included 172 pathologically confirmed lymph nodes (100 benign, 72 metastatic). SRUS was performed to derive density and velocity parameters, with central‐to‐peripheral ratios and temporal changes calculated. Static and dynamic models were constructed using univariate analysis, least absolute shrinkage and selection operator (LASSO), and logistic regression. Model performance was assessed by cross‐validation, area under the receiver operating characteristic curve (AUC), calibration, decision curve analysis, and clinical impact curve.

Results

Metastatic lymph nodes showed significantly lower central‐to‐peripheral ratios of density and velocity parameters but higher relative temporal changes in density SD and velocity SD compared with benign nodes (all P < .05). The static time‐point model retained 2 SRUS variables (Mean.Density_C_P_T2, Max.Density_C_P_T3), yielding a full‐sample AUC of 0.8607. The temporal change model included 2 dynamic parameters (Velocity SD change from T1 to T2, Mean density change from T2 to T3) and achieved a higher AUC of 0.8715, with better accuracy, specificity, and model fit. Both models showed favorable calibration and clinical net benefit.

Conclusion

Quantitative SRUS parameters effectively reflect pathological angiogenesis in metastatic lymph nodes. The temporal change model provides superior diagnostic performance over the static time‐point model and may serve as a reliable noninvasive tool for distinguishing benign from metastatic lymph nodes.

Schlagwörter

Stichwörter der Autor:innen

diagnostic modellymph nodemetastasissuper‐resolution ultrasoundtemporal dynamic change

Autor:innen und Institutionen

  • Department of Ultrasound, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China.

ORCID-Profile: Qing Xie, Ruixue Cui, Ming Li, Huawei Zhang

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Shandong Province

Zitieren

APA

Xie, Q., Cui, R., Zhao, Z., Li, M., Gao, Y., & Zhang, H. (2026). Super‐Resolution Ultrasound for Lymph Node Evaluation: Diagnostic Value of Static Time‐Point Parameters Versus Dynamic Temporal Changes. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.70497

Vancouver

Xie Q, Cui R, Zhao Z, Li M, Gao Y, Zhang H. Super‐Resolution Ultrasound for Lymph Node Evaluation: Diagnostic Value of Static Time‐Point Parameters Versus Dynamic Temporal Changes. Journal of Ultrasound in Medicine. 2026. doi:10.1002/jum.70497

BibTeX
@article{Xie2026,
  author = {Xie, Qing and Cui, Ruixue and Zhao, Zhendan and Li, Ming and Gao, Yuehua and Zhang, Huawei},
  title = {Super‐Resolution Ultrasound for Lymph Node Evaluation: Diagnostic Value of Static Time‐Point Parameters Versus Dynamic Temporal Changes},
  journal = {Journal of Ultrasound in Medicine},
  year = {2026},
  doi = {10.1002/jum.70497}
}
Kostenlos starten →