Validation of a Novel Point‐of‐Care Ultrasound Method for Estimating Central Venous Pressure in Critically Ill Patients
Journal of Ultrasound in Medicine · 10.09.2026
DOI: 10.1002/jum.70449 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Ultrasound in Medicine, online erschienen am 10.09.2026. Verfasst von Carmelo José Espinosa-Almanza und 2 weiteren Autor:innen. Beteiligte Einrichtung: Departamento de Medicina Interna, Facultad de Medicina, Universidad Nacional de Colombia, Bogotá, Colombia. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben.
Abstract (Originalsprache)
Objectives
To validate an ultrasound‐based method for noninvasive estimation of central venous pressure (CVP) in critically ill patients and compare its performance with invasively measured CVP.
Methods
We conducted an analytical cross‐sectional study in adults admitted to a general intensive care unit. Patients with a central venous catheter and CVP monitoring through an electronic transducer were included. Ultrasound‐estimated CVP (CVPus) was calculated using the method described by Istrail et al, which combines right atrial depth and jugular venous distension height. Correlation, paired mean differences, Bland–Altman agreement, and discriminative performance for invasive CVP thresholds of ≥5 and ≥10 mmHg were assessed.
Results
Seventy‐five patients were included; CVPus was feasible in 70. Mean invasive CVP was 5.50 ± 3.80 mmHg; 53.3% of patients had CVP ≥5 mmHg and 21.3% had CVP ≥10 mmHg. CVPus showed a moderate positive correlation with invasive CVP ( r = 0.61; p < .001). Mean invasive CVP and mean CVPus were 5.26 and 5.59 mmHg, respectively ( p = .375). Bland–Altman analysis showed a mean bias of −0.33 mmHg, with 95% limits of agreement from −6.37 to 5.72 mmHg. The area under the ROC curve was 0.83 (95% CI, 0.68–0.99) for invasive CVP ≥10 mmHg and 0.81 (95% CI, 0.71–0.91) for invasive CVP ≥5 mmHg.
Conclusions
The Istrail et al ultrasound method showed favorable overall performance for noninvasive CVP estimation in critically ill patients. Its low mean bias and good discriminative ability support its use as a complementary bedside tool, although agreement with invasive measurement remains limited.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Departamento de Medicina Interna, Facultad de Medicina, Universidad Nacional de Colombia, Bogotá, Colombia.
- Unidad de Cuidados Intensivos, Hospital Universitario Nacional de Colombia, Grupo de Investigación en Cuidados Intensivos de la Universidad Nacional de Colombia (GICI-UN), Bogotá, Colombia.
- Unidad de Cuidados Intensivos, Hospital Universitario Nacional de Colombia, Grupo de Interés en Ultrasonido Enfocado HUN-UNAL, Bogotá, Colombia.
- Unidad de Cuidados Intensivos, Hospital Universitario Nacional de Colombia, Bogotá, Colombia.
ORCID-Profile: Carmelo José Espinosa-Almanza, Jorge Leonardo Támara-Rivera, Héctor Andrés Ruiz-Ávila
Zitieren
APA
Espinosa-Almanza, C. J., Támara-Rivera, J. L., & Ruiz-Ávila, H. A. (2026). Validation of a Novel Point‐of‐Care Ultrasound Method for Estimating Central Venous Pressure in Critically Ill Patients. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.70449
Vancouver
Espinosa-Almanza CJ, Támara-Rivera JL, Ruiz-Ávila HA. Validation of a Novel Point‐of‐Care Ultrasound Method for Estimating Central Venous Pressure in Critically Ill Patients. Journal of Ultrasound in Medicine. 2026. doi:10.1002/jum.70449
BibTeX
@article{EspinosaAlmanza2026,
author = {Espinosa-Almanza, Carmelo José and Támara-Rivera, Jorge Leonardo and Ruiz-Ávila, Héctor Andrés},
title = {Validation of a Novel Point‐of‐Care Ultrasound Method for Estimating Central Venous Pressure in Critically Ill Patients},
journal = {Journal of Ultrasound in Medicine},
year = {2026},
doi = {10.1002/jum.70449}
}