Diagnostic Value of O‐ RADS , CA125 , and Ultra Microangiography in Differentiating Benign and Malignant Adnexal Masses
Journal of Ultrasound in Medicine · 2026-12 · 45 (12) · 2749-2761
DOI: 10.1002/jum.70369 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Ultrasound in Medicine, online erschienen am 17.07.2026. Verfasst von Mei-Ya Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound Medicine, Jining Medical University, Jining, China. Hauptthemen laut MEDLINE: CA-125 Antigen, Adnexal Diseases, Angiography, Membrane Proteins. Die Arbeit nennt 19 Literaturangaben.
Abstract (Originalsprache)
Objectives
This study aimed to evaluate the diagnostic performance of the Ovarian Adnexal Reporting and Data System (O‐RADS, version 2022), the tumor marker carbohydrate antigen 125 (CA125), and ultra microangiography (UMA) in distinguishing benign from malignant adnexal masses.
Methods
A retrospective analysis of 320 patients with surgically confirmed adnexal masses was conducted. All patients underwent 2‐dimensional ultrasound (transvaginal, transabdominal, or combined), UMA examination, O‐RADS 22 classification (Categories 2–5), SUMA flow pixel ratio measurement, and preoperative tumor marker testing (CA125, CA19‐9, HE4). Univariate and multivariate logistic regression analyses were performed. Receiver operating characteristic (ROC) curves and area under the curve (AUC) values were calculated for statistically significant variables.
Results
Two hundred and forty‐nine (77.8%) were benign and 71 (22.2%) non‐benign. Malignancy detection rates for O‐RADS 22 categories 2–5 were 0.00, 6.88, 42.37, and 77.78%, respectively. Mature teratoma (22.2%) and serous cystadenoma (16.9%) were the most common benign lesions; high‐grade serous adenocarcinoma (10.9%) and borderline serous tumor (5.3%) were the most common malignant lesions. Univariate analysis showed O‐RADS 22 classification, SUMA flow pixel ratio, CA125, HE4, menopausal status, age, menopausal duration, and lymphocyte count were significantly associated with diagnosis ( p < .05). Multivariate analysis identified O‐RADS 22 classification, SUMA flow pixel ratio, CA125, and age as independent risk factors ( p < .05). AUC values were 0.724, 0.794, 0.826, and 0.770, respectively; combined AUC was 0.906 (95% CI: 0.869–0.942), significantly superior to single parameters ( p < .05, DeLong test). Combined application is particularly valuable when CA19‐9 and/or HE4 are positive in mature teratomas or endometriotic cysts.
Conclusion
Combined O‐RADS, CA125, and UMA significantly enhance diagnostic accuracy for adnexal masses compared to individual modalities.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Ultrasound Medicine, Jining Medical University, Jining, China.
- Department of Ultrasound Medicine, Jining No. 1 People's Hospital, Jining, China.
ORCID-Profile: Ping Chen
Zitieren
APA
Liu, M. Y., Kong, Q. F., Su, E. H., Zhang, Q. Q., Zhang, J. Y., & Chen, P. (2026). Diagnostic Value of O‐ RADS , CA125 , and Ultra Microangiography in Differentiating Benign and Malignant Adnexal Masses. Journal of Ultrasound in Medicine, 45(12), 2749-2761. https://doi.org/10.1002/jum.70369
Vancouver
Liu MY, Kong QF, Su EH, Zhang QQ, Zhang JY, Chen P. Diagnostic Value of O‐ RADS , CA125 , and Ultra Microangiography in Differentiating Benign and Malignant Adnexal Masses. Journal of Ultrasound in Medicine. 2026;45(12):2749-2761. doi:10.1002/jum.70369
BibTeX
@article{Liu2026,
author = {Liu, Mei-Ya and Kong, Qing-Feng and Su, En-Hong and Zhang, Qian-Qian and Zhang, Jie-Ying and Chen, Ping},
title = {Diagnostic Value of O‐ RADS , CA125 , and Ultra Microangiography in Differentiating Benign and Malignant Adnexal Masses},
journal = {Journal of Ultrasound in Medicine},
year = {2026},
volume = {45},
number = {12},
pages = {2749--2761},
doi = {10.1002/jum.70369}
}
EUVIMED