EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access

Diagnostic Performance of Duplex Ultrasonography in Post‐Radiation Common Carotid Artery Stenosis

Min-Shuo Chen, Jian-Lin Jiang iD, Chih-Hua Yeh, Ting-Yu Chang, Joseph Tung-Chieh Chang, Bing-Shen Huang, Chien-Yu Lin, Yi-Ming Wu, Chun-Wei Chang iD, Yeu-Jhy Chang, Hsiu-Chuan Wu, Tsong-Hai Lee und 1 weitere

Journal of Ultrasound in Medicine · 2026-09 · 45 (9) · 1843-1851

DOI: 10.1002/jum.70232 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Ultrasound in Medicine, online erschienen am 08.03.2026. Verfasst von Min-Shuo Chen und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan. Hauptthemen laut MEDLINE: Carotid Stenosis, Ultrasonography, Doppler, Duplex, Carotid Artery, Common, Head and Neck Neoplasms. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Chang Gung Memorial Hospital, National Science and Technology Council of Taiwan, National Science and Technology Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Whether established diagnostic criteria of carotid duplex ultrasonography (CDU) for atherosclerotic carotid artery stenosis are applicable to radiation vasculopathy in head and neck cancer (HNC) patients remains uncertain. This study aimed to validate the diagnostic accuracy of CDU for screening radiation‐induced common carotid artery (CCA) stenosis.

Methods

We enrolled 134 HNC patients with 268 carotid arteries, all of whom underwent CDU and computed tomographic angiography. Diameter stenosis and hemodynamic parameters were assessed on CDU, with ≥50% stenosis on computed tomographic angiography serving as the reference standard. Diagnostic performance was evaluated using sensitivity, specificity, PPV, NPV, and receiver operating characteristic (ROC) analysis to identify optimal cutoff values.

Results

Using a B‐mode cutoff of 50% to detect ≥50% CCA stenosis, the sensitivity, specificity, PPV, and NPV were 85.2, 88.1, 45.1, and 98.1%, respectively. The optimal B‐mode threshold of 53%, which yielded a sensitivity of 75.9%, specificity of 91.4%, PPV of 51.2%, and NPV of 96.9%, with an area under the ROC curve (AUROC) of 0.894. In comparison, the optimal PSV threshold of 203 cm/s showed lower sensitivity (51.7%) but higher specificity (99.2%), with a PPV of 88.2%, NPV of 94.6%, and an AUROC of 0.698. Combining B‐mode and PSV criteria resulted in an AUROC of 0.891, offering minimal incremental diagnostic benefit compared with B‐mode assessment alone.

Conclusions

B‐mode CDU may be a feasible screening tool for radiation‐induced CCA stenosis. A B‐mode threshold of 53% achieved diagnostic performance comparable to combined B‐mode and velocity criteria for detecting ≥50% stenosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carotid StenosisUltrasonography, Doppler, DuplexCarotid Artery, CommonHead and Neck NeoplasmsRadiation InjuriesHumansSensitivity and SpecificityFemaleReproducibility of ResultsCross-Sectional StudiesMaleAgedMiddle AgedUltrasonography, Carotid Arteries

Stichwörter der Autor:innen

CT angiographycarotid artery stenosiscarotid duplex ultrasoundhead and neck cancerradiation vasculopathy

Autor:innen und Institutionen

  • Department of Neurology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan.
  • School of Medicine, College of Medicine, Chang Gung University, Taoyuan, Taiwan.
  • Department of Neuroradiology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan.
  • Department of Radiation Oncology, Proton and Radiation Therapy Center, Chang Gung Medical Foundation, Linkou Chang Gung Memorial Hospital, Taoyuan, Taiwan.
  • Taipei Chang Gung Head & Neck Oncology Group, Chang Gung Memorial Hospital Linkou Medical Center, Taoyuan, Taiwan.
  • Radiation Research Core Laboratory, Chang Gung University/ Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan.

ORCID-Profile: Jian-Lin Jiang, Chun-Wei Chang, Chi-Hung Liu

Förderung

  • Chang Gung Memorial Hospital
  • National Science and Technology Council of Taiwan
  • National Science and Technology Council

Zitieren

APA

Chen, M. S., Jiang, J. L., Yeh, C. H., Chang, T. Y., Chang, J. T., Huang, B. S., Lin, C. Y., Wu, Y. M., Chang, C. W., Chang, Y. J., Wu, H. C., Lee, T. H., & Liu, C. H. (2026). Diagnostic Performance of Duplex Ultrasonography in Post‐Radiation Common Carotid Artery Stenosis. Journal of Ultrasound in Medicine, 45(9), 1843-1851. https://doi.org/10.1002/jum.70232

Vancouver

Chen MS, Jiang JL, Yeh CH, Chang TY, Chang JT, Huang BS, et al. Diagnostic Performance of Duplex Ultrasonography in Post‐Radiation Common Carotid Artery Stenosis. Journal of Ultrasound in Medicine. 2026;45(9):1843-1851. doi:10.1002/jum.70232

BibTeX
@article{Chen2026,
  author = {Chen, Min-Shuo and Jiang, Jian-Lin and Yeh, Chih-Hua and Chang, Ting-Yu and Chang, Joseph Tung-Chieh and Huang, Bing-Shen and Lin, Chien-Yu and Wu, Yi-Ming and Chang, Chun-Wei and Chang, Yeu-Jhy and Wu, Hsiu-Chuan and Lee, Tsong-Hai and Liu, Chi-Hung},
  title = {Diagnostic Performance of Duplex Ultrasonography in Post‐Radiation Common Carotid Artery Stenosis},
  journal = {Journal of Ultrasound in Medicine},
  year = {2026},
  volume = {45},
  number = {9},
  pages = {1843--1851},
  doi = {10.1002/jum.70232}
}
Kostenlos starten →