Evaluating the Need for Multiple Ultrasound Measurements for Accurate Prediction of Birthweight Using Estimated Fetal Weight
Journal of Ultrasound in Medicine · 2026
DOI: 10.1002/jum.70180 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Ultrasound in Medicine, 2026. Verfasst von Madeleine E St Ville und 3 weiteren Autor:innen. Beteiligte Einrichtung: Biostatistics and Bioinformatics Branch, Division of Population Health Research, Division of Intramural Research, Eunice Kennedy Shriver National Ins…. Hauptthemen laut MEDLINE: Ultrasonography, Prenatal, Birth Weight, Fetal Weight. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NICHD NIH HHS, Intramural NIH HHS.
Abstract (Originalsprache)
Objectives
To evaluate whether averaging replicate fetal biometry measurements during an examination improves estimated fetal weight (EFW) accuracy for predicting birthweight compared with a single set and to assess how variability in fetal biometric measurements changes across gestation.
Methods
Secondary analysis of the Eunice Kennedy Shriver National Institute of Child and Health and Human Development (NICHD) Fetal Growth Studies‐Singletons. At each study visit, fetal head circumference (HC), abdominal circumference (AC), and femur length (FL) were measured in triplicate to compute EFW at each of 6 study visits (0–5). Variability among replicates was assessed across gestation using boxplots and two‐way repeated measures ANOVA. For participants with visit 5 EFW (n = 1101), predictive accuracy of each individual measurement and their averages was compared with birthweight using average percent error and proportion within 10% of birthweight. One‐way ANOVA and chi‐square tests were applied. Sensitivity analyses included second‐to‐last visit, subgroups classified as small‐ or large‐for‐gestational age, and a subgroup of participants who delivered within 3 days of visit 5.
Results
Across visits, replicate HC, AC, and FL showed minimal variability, with no significant differences among replicates or across gestation. At visit 5, average EFW and standard deviations were similar across individual and averaged measurements. Percent errors ranged from 8.2 to 8.5% ( p = .999), and proportion within 10% of birthweight ranged from 64.4 to 66.4% ( p = .954). Sensitivity analyses produced similarly null findings.
Conclusions
In a controlled research setting with credentialed sonographers and standardized protocols, averaging replicate fetal biometric measurements did not improve EFW prediction of birthweight. A single high‐quality measurement of fetal biometry may be sufficient, although further research is warranted to confirm generalizability to routine clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biostatistics and Bioinformatics Branch, Division of Population Health Research, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of H…
- Epidemiology Branch, Division of Population Health Research, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes Health, Bethesda, Maryla…
ORCID-Profile: Madeleine E St Ville, Katherine L Grantz, Zhen Chen
Förderung
- NIH HHS
- NICHD NIH HHS
- Intramural NIH HHS
- National Institutes of Health
Zitieren
APA
St Ville, M. E., Grantz, K. L., Gleason, J. L., & Chen, Z. (2026). Evaluating the Need for Multiple Ultrasound Measurements for Accurate Prediction of Birthweight Using Estimated Fetal Weight. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.70180
Vancouver
St Ville ME, Grantz KL, Gleason JL, Chen Z. Evaluating the Need for Multiple Ultrasound Measurements for Accurate Prediction of Birthweight Using Estimated Fetal Weight. Journal of Ultrasound in Medicine. 2026. doi:10.1002/jum.70180
BibTeX
@article{StVille2026,
author = {St Ville, Madeleine E and Grantz, Katherine L and Gleason, Jessica L and Chen, Zhen},
title = {Evaluating the Need for Multiple Ultrasound Measurements for Accurate Prediction of Birthweight Using Estimated Fetal Weight},
journal = {Journal of Ultrasound in Medicine},
year = {2026},
doi = {10.1002/jum.70180}
}
EUVIMED