International Multicentric Study on Ultrasound Characteristics, Layer Location, and Corporal Distribution of Granulomas After Cosmetic Fillers Injections
Journal of Ultrasound in Medicine · 2025
DOI: 10.1002/jum.16700 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Ultrasound in Medicine, 2025. Verfasst von Ximena Wortsman und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dermatology, Faculty of Medicine, Universidad de Chile, Santiago, Chile. Hauptthemen laut MEDLINE: Dermal Fillers, Cosmetic Techniques, Granuloma, Foreign-Body, Granuloma. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 39 Literaturangaben.
Abstract (Originalsprache)
Objectives
To provide insight into the characteristics, layer locations, and corporal distribution of the granulomatous reactions to cosmetic fillers.
Methods
An international retrospective multicentric study was performed in centers that scan complications of cosmetic fillers. Inclusion criteria were patients with previous injections of known cosmetic fillers confirmed by ultrasound and ultrasonographic features of granulomatous reactions such as hypoechoic nodules, pseudonodules, or hypoechoic tissue surrounding the deposit regions. The ultrasound studies followed the published guidelines for performing dermatologic ultrasound examinations.
Results
A total of 240 cases met the criteria. The leading fillers previously injected were 50.4% hyaluronic acid, 18.8% poly‐L‐lactic acid, 8.3% polymethylmethacrylate, 6.3% calcium hydroxyapatite, and 3.8% silicone oil. The main regions of granulomas were the lower lid, infraorbital, and medial cheek in 41.7%, the perioral region and lips in 19.2%, the lateral jaw and cheek in 14.6%, and the chin, pre‐jowl, and medial jaw in 12.5%. The layers involved by the granulomatous reaction were hypodermis in 37.1%, the deep fat pad in 8.9%, the periosteum in 5.8%, the combination of hypodermis, deep fat pad, and muscle in 5.8%, and the combination of hypodermis, fascia, subfascial, deep fat pad, and muscle in 5.4%. The predominant corporal locations were the face, submandibular, and anterior neck, with 95.8% being 87.5% in the face.
Conclusion
Ultrasound can provide valuable and detailed anatomical information supporting diagnosis and management as well as valuable insights into the granulomatous reactions to fillers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Dermatology, Faculty of Medicine, Universidad de Chile, Santiago, Chile.
- Department of Dermatology, School of Medicine, Pontificia Universidad Catolica de Chile, Santiago, Chile.
- Department of Dermatology, Miller School of Medicine, University of Miami, Miami, Florida, USA.
- Institute for Diagnostic Imaging and Research of the Skin and Soft Tissues, Santiago, Chile.
- Highly Specialized Ultrasound Center, Bogotá, Colombia.
- Centre Mèdic de Cabo Bové, Martorell, Spain.
ORCID-Profile: Ximena Wortsman, Stella Desyatnikova
Zitieren
APA
Wortsman, X., Valderrama, Y., Ortiz-Orellana, G., Gonzalez, C., de Cabo, F., Desyatnikova, S., Cavallieri, F. A., Barrera, P., & Sigrist, R. (2025). International Multicentric Study on Ultrasound Characteristics, Layer Location, and Corporal Distribution of Granulomas After Cosmetic Fillers Injections. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.16700
Vancouver
Wortsman X, Valderrama Y, Ortiz-Orellana G, Gonzalez C, de Cabo F, Desyatnikova S, et al. International Multicentric Study on Ultrasound Characteristics, Layer Location, and Corporal Distribution of Granulomas After Cosmetic Fillers Injections. Journal of Ultrasound in Medicine. 2025. doi:10.1002/jum.16700
BibTeX
@article{Wortsman2025,
author = {Wortsman, Ximena and Valderrama, Yessenia and Ortiz-Orellana, Gabriela and Gonzalez, Claudia and de Cabo, Francisco and Desyatnikova, Stella and Cavallieri, Fernanda Aquino and Barrera, Patricia and Sigrist, Rosa},
title = {International Multicentric Study on Ultrasound Characteristics, Layer Location, and Corporal Distribution of Granulomas After Cosmetic Fillers Injections},
journal = {Journal of Ultrasound in Medicine},
year = {2025},
doi = {10.1002/jum.16700}
}
EUVIMED