Advancements in Three‐Dimensional Super‐Resolution Ultrasound Imaging
Journal of Ultrasound in Medicine · 2025-07 · 44 (7) · 1157-1174
DOI: 10.1002/jum.16682 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Ultrasound in Medicine, online erschienen am 12.03.2025. Verfasst von Debabrata Ghosh und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics and Communication Engineering, Thapar Institute of Engineering and Technology, Patiala, India. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Contrast Media, Image Enhancement. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NCI NIH HHS, NIDDK NIH HHS.
Abstract (Originalsprache)
The lack of sensibility of traditional ultrasound (US) imaging to the slow blood flow in small vessels resulted in the development of microbubble (MB) contrast agents. These MBs are given intravenously, and US imaging can detect them quite effectively. This noninvasive imaging method, known as contrast‐enhanced US (CEUS), now makes it possible to accurately assess tissue perfusion and blood flow. Though CEUS offers several benefits, diffraction restricts the spatial resolution of all US imaging systems to length scales equal to roughly half the wavelength of the transmitted US beam. Based on individual MB detection and localization, the recently developed super‐resolution US (SRUS) imaging method has shown unprecedentedly high spatial resolution exceeding the physical diffraction limit. It is now possible to visualize the microvasculature beyond the diffraction‐limited resolution by localizing spatially isolated MBs across several frames. The highest resolution possible at clinical US frequencies can be on the order of several micrometers when tissue and probe motion are not present. Enhancing the functional study of tissue microvascular networks with structural data could lead to improved disease management. Through the localization and tracking of MBs, SRUS may reconstruct images of the microvasculature with resolution exceeding the diffraction limit in both 2‐dimensional (2D) and 3‐dimensional (3D) space. In contrast to the 2D approach, 3D SRUS imaging does not suffer from out‐of‐plane motion and can offer volumetric coverage with super‐resolution in all three dimensions. Research has used two primary methods for 3D SRUS imaging including arrays that can electronically gather volumetric information or mechanically scanning the volume with a linear probe to produce a stack of 2D SRUS images. This manuscript aims to offer a comprehensive review of 3D SRUS imaging, clarifying methodologies, clinical applications, and notable challenges that could motivate future research and help facilitate clinical translation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Electronics and Communication Engineering, Thapar Institute of Engineering and Technology, Patiala, India.
- Department of Biomedical Engineering, Department of Small Animal Clinical Sciences, Texas A&M University, College Station, Texas, USA.
ORCID-Profile: Kenneth Hoyt
Förderung
- NIBIB NIH HHS
- NCI NIH HHS
- NIDDK NIH HHS
- Ministry of Education, India
- NIH HHS
- National Institutes of Health
Zitieren
APA
Ghosh, D., & Hoyt, K. (2025). Advancements in Three‐Dimensional Super‐Resolution Ultrasound Imaging. Journal of Ultrasound in Medicine, 44(7), 1157-1174. https://doi.org/10.1002/jum.16682
Vancouver
Ghosh D, Hoyt K. Advancements in Three‐Dimensional Super‐Resolution Ultrasound Imaging. Journal of Ultrasound in Medicine. 2025;44(7):1157-1174. doi:10.1002/jum.16682
BibTeX
@article{Ghosh2025,
author = {Ghosh, Debabrata and Hoyt, Kenneth},
title = {Advancements in Three‐Dimensional Super‐Resolution Ultrasound Imaging},
journal = {Journal of Ultrasound in Medicine},
year = {2025},
volume = {44},
number = {7},
pages = {1157--1174},
doi = {10.1002/jum.16682}
}
EUVIMED