Fachartikel in der Zeitschrift Journal of Ultrasound in Medicine, 2025. Verfasst von Fu-Shun Pan und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital, Sun Yat-Sen University, Guan…. Hauptthemen laut MEDLINE: Stents, Ultrasonography, Doppler, Duplex, Renal Artery, Kidney Transplantation. Die Arbeit nennt 22 Literaturangaben.
Abstract (Originalsprache)
Objective
To evaluate the diagnosis performance of duplex ultrasound (DUS) in predicting transplanted renal artery (TRA) in‐stent restenosis (ISR).
Methods
In this retrospective study, 112 consecutive patients underwent stenting due to TRA stenosis. DUS were performed within 1 week after stenting for baseline value, and after ≥3 months follow‐up for surveillance of ISR. The DUS measurements included peak systolic velocity (PSV) and PSV ratio of renal artery stent to iliac artery (RIR). Receiver operating characteristic (ROC) curves were applied to evaluate the diagnosis performance of DUS parameters in predicting ISR.
Results
There were 69 patients (28 men; age, 38.3 ± 15.1 years) who obtained 92 adequate paired DUS and CTA after stenting, which were classified as ISR group (26 TRAs) and non‐ISR group (66 TRAs). There was no difference between the two groups for baseline DUS features, including PSV B and RIR B . The late DUS features including stent PSV L (475.5 vs 261.9 cm/s), RIR L (4.10 vs 2.18), and stent PSV L /PSV B (2.72 vs 1.14) were significantly higher in the ISR group than the non‐ISR group (all P < .0001). Stent PSV L , RIR L , and PSV L /PSV B demonstrated comparable AUCs in predicting ISR. However, the sensitivity and specificity of PSV L /PSV B in predicting ISR were 92.3 and 93.5%, respectively, demonstrating higher specificity with equivalent sensitivity than PSV L and higher sensitivity with equivalent specificity than RIR L .
Conclusions
DUS is an accurate technique to identify TRA‐ISR. We suggest all patients should undergo DUS immediately after stenting to establish baseline value and aid in evaluating ISR at late follow‐up.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
- Organ Transplant Center, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China.
ORCID-Profile: Fu-Shun Pan
Zitieren
APA
Pan, F. S., Yang, D. P., & Deng, R. H. (2025). Duplex Ultrasound in Evaluating Transplanted Renal Artery In‐Stent Restenosis. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.16656
Vancouver
Pan FS, Yang DP, Deng RH. Duplex Ultrasound in Evaluating Transplanted Renal Artery In‐Stent Restenosis. Journal of Ultrasound in Medicine. 2025. doi:10.1002/jum.16656
BibTeX
@article{Pan2025,
author = {Pan, Fu-Shun and Yang, Dao-Peng and Deng, Rong-Hai},
title = {Duplex Ultrasound in Evaluating Transplanted Renal Artery In‐Stent Restenosis},