EUVIMEDEUVIMED entdecken
Crossref

Shear Wave Elastography as a Supplement Tool in Differentiating Benign and Malignant Axillary Lymph Nodes

Aishwarya Sharma iD, Ravinder Kaur iD, Narinder Kaur iD, Uma Handa iD, Usha Dalal iD, Anurag Gupta

Journal of Ultrasound in Medicine · 2025

DOI: 10.1002/jum.16653 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Ultrasound in Medicine, 2025. Verfasst von Aishwarya Sharma und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiodiagnosis, Government Medical College and Hospital, Chandigarh, India. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Lymph Nodes, Lymphatic Metastasis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To determine the efficacy of quantitative shear wave elastography in differentiating benign and malignant axillary lymph nodes (ALN).

Methods

Exactly 127 lymph nodes from 127 patients with clinically palpable axillary swelling were examined by both B‐mode sonography and elastography from November 2022 to March 2024. Gray‐scale sonograms were evaluated based on: the short‐axis diameter, shape, hilum, maximum cortical thickness, and border of the ALN. Shear wave elastography determined the mean elasticity modulus ( E ‐mean) and elasticity ratio ( E ‐ratio). Fine needle aspiration cytology or histopathological examination was kept as the gold standard and diagnostic performance shear wave elastography was compared.

Results

The data showed that out of 127 lymph nodes, 77 (60.6%) were benign and 50 (39.4%) were malignant based on pathological results. The E ‐mean for malignant lymph nodes (mean, 73.15 kPa) was higher than that for benign lymph nodes (mean, 21.47 kPa; P < .001). The area under the receiver operating characteristic curve for E ‐ratio in predicting malignant and benign lymph nodes was 0.897 (95% CI: 0.839–0.955). The E ‐ratio for malignant lymph nodes was also higher (mean, 10.2) than for benign nodes (mean, 2.95; P < .001). The area under the receiver operating characteristic curve for E ‐ratio in predicting malignant and benign lymph nodes was 0.816 (95% CI: 0.733–0.899).

Conclusion

Our results showed a significant association between tissue elasticity and pathological correlation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesLymph NodesLymphatic MetastasisHumansFemaleDiagnosis, DifferentialMiddle AgedMaleAxillaAdultAgedYoung AdultAged, 80 and overSensitivity and SpecificityReproducibility of ResultsAdolescent

Stichwörter der Autor:innen

axillary lymph nodebreast cancerelastographymetastasisshear wave elastographytuberculosis

Autor:innen und Institutionen

  • Department of Radiodiagnosis, Government Medical College and Hospital, Chandigarh, India.
  • Department of Pathology, Government Medical College and Hospital, Chandigarh, India.
  • Department of Surgery, Government Medical College and Hospital, Chandigarh, India.

ORCID-Profile: Aishwarya Sharma, Ravinder Kaur, Narinder Kaur, Uma Handa, Usha Dalal

Zitieren

APA

Sharma, A., Kaur, R., Kaur, N., Handa, U., Dalal, U., & Gupta, A. (2025). Shear Wave Elastography as a Supplement Tool in Differentiating Benign and Malignant Axillary Lymph Nodes. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.16653

Vancouver

Sharma A, Kaur R, Kaur N, Handa U, Dalal U, Gupta A. Shear Wave Elastography as a Supplement Tool in Differentiating Benign and Malignant Axillary Lymph Nodes. Journal of Ultrasound in Medicine. 2025. doi:10.1002/jum.16653

BibTeX
@article{Sharma2025,
  author = {Sharma, Aishwarya and Kaur, Ravinder and Kaur, Narinder and Handa, Uma and Dalal, Usha and Gupta, Anurag},
  title = {Shear Wave Elastography as a Supplement Tool in Differentiating Benign and Malignant Axillary Lymph Nodes},
  journal = {Journal of Ultrasound in Medicine},
  year = {2025},
  doi = {10.1002/jum.16653}
}
Kostenlos starten →