EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Reliability and Availability of the 2017 EULAR ‐ OMERACT Scoring System for Ultrasound Synovitis Assessment

Chenyang Zhao, Nan Zhuang iD, Yusen Zhang, Heng Lv, Weiwei Zhang, Yuzhou Shen, Wangjie Wu, Yun Tian, Lu Xie, Gengmin Zhou, Haiyu Luo iD, Li Qiu und 2 weitere

Journal of Ultrasound in Medicine · 2025

DOI: 10.1002/jum.16607 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Ultrasound in Medicine, 2025. Verfasst von Chenyang Zhao und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasonography, Peking University Shenzhen Hospital, Shenzhen, China. Hauptthemen laut MEDLINE: Synovitis, Ultrasonography, Arthritis, Rheumatoid. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Natural Science Foundation of China, Science Technology and Innovation Commission of Shenzhen Municipality in China, General Program for Clinical Research at Peking University Shenzhen Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the availability and reliability of the European League Against Rheumatisms Outcome Measures in Rheumatology Synovitis (EULAR‐OMERACT) scoring system among radiologists with different levels of musculoskeletal ultrasound (US) experience in assessing synovitis in patients with rheumatoid arthritis (RA).

Method

The patients with RA were retrospectively recruited from January 2020 to March 2022. Five radiologists with different levels of US experience were recruited for the reader study (R1–5), which included two parts. The participating radiologists first read 120 gray‐scale (GS) and 120 Doppler US images twice, before and after a standard training program. In the first part, they semi‐quantitatively scored the images from 0 to 3 based on the EULAR‐OMERACT scoring system. In the second part, they read and scored 165 paired GS and Doppler images two times in 1 month using the EULAR‐OMERACT scoring system. The correlation between the sum of the GSUS and power Doppler US (PDUS) image scores and the clinical scores was assessed.

Result

The intra‐rater agreement of the five radiologists was good for the EULAR‐OMERACT scoring system, with κ ranging from 0.72 to 0.94 for GSUS and from 0.81 to 0.97 for PDUS. The inter‐rater agreement among the experts was good to very good in the EULAR‐OMERACT scoring system ( κ : 0.76–0.94 for GSUS and 0.80–0.96 for PDUS). The sum of the GSUS and PDUS scores in the EULAR‐OMERACT scoring system was moderate to highly positively correlated with the clinical scores ( ρ of GSUS: 0.58–0.79, ρ of PDUS: 0.57–0.70 for disease activity score in 28 joints C‐reactive protein) after training.

Conclusion

The EULAR‐OMERACT scoring system is a reliable method for evaluating synovitis in RA and shows potential for disease assessment and follow‐up in patients with RA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SynovitisUltrasonographyArthritis, RheumatoidHumansReproducibility of ResultsFemaleMaleRetrospective StudiesMiddle AgedSeverity of Illness IndexAdultObserver VariationAged

Stichwörter der Autor:innen

rheumatoid arthritissynovitisultrasound

Autor:innen und Institutionen

  • Department of Ultrasonography, Peking University Shenzhen Hospital, Shenzhen, China.
  • Department of Rheumatology and Immunology, Peking University Shenzhen Hospital, Shenzhen, China.
  • Department of Ultrasound, West China Hospital of Sichuan University, Chengdu, China.

ORCID-Profile: Nan Zhuang, Haiyu Luo, Haiqin Xie

Förderung

  • National Natural Science Foundation of China
  • Science Technology and Innovation Commission of Shenzhen Municipality in China
  • General Program for Clinical Research at Peking University Shenzhen Hospital
  • Shenzhen Key Medical Discipline Construction Fund
  • Sanming Project of Medicine in Shenzhen
  • Sanming Project of Medicine in Shenzen Municipality

Zitieren

APA

Zhao, C., Zhuang, N., Zhang, Y., Lv, H., Zhang, W., Shen, Y., Wu, W., Tian, Y., Xie, L., Zhou, G., Luo, H., Qiu, L., Sun, D., & Xie, H. (2025). Reliability and Availability of the 2017 EULAR ‐ OMERACT Scoring System for Ultrasound Synovitis Assessment. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.16607

Vancouver

Zhao C, Zhuang N, Zhang Y, Lv H, Zhang W, Shen Y, et al. Reliability and Availability of the 2017 EULAR ‐ OMERACT Scoring System for Ultrasound Synovitis Assessment. Journal of Ultrasound in Medicine. 2025. doi:10.1002/jum.16607

BibTeX
@article{Zhao2025,
  author = {Zhao, Chenyang and Zhuang, Nan and Zhang, Yusen and Lv, Heng and Zhang, Weiwei and Shen, Yuzhou and Wu, Wangjie and Tian, Yun and Xie, Lu and Zhou, Gengmin and Luo, Haiyu and Qiu, Li and Sun, Desheng and Xie, Haiqin},
  title = {Reliability and Availability of the 2017 EULAR ‐ OMERACT Scoring System for Ultrasound Synovitis Assessment},
  journal = {Journal of Ultrasound in Medicine},
  year = {2025},
  doi = {10.1002/jum.16607}
}
Kostenlos starten →