Cranial Point‐of‐Care Ultrasound for Neonatal Providers
Journal of Ultrasound in Medicine · 2024-06 · 43 (6) · 1089-1097
DOI: 10.1002/jum.16437 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Journal of Ultrasound in Medicine, online erschienen am 25.02.2024. Verfasst von Sarah E Kolnik und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatrics, Division of Neonatology, University of Washington/Seattle Children's Hospital, Seattle, Washington, USA. Hauptthemen laut MEDLINE: Feasibility Studies, Point-of-Care Systems, Ultrasonography. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 42 Literaturangaben.
Abstract (Originalsprache)
Objective
Despite strong evidence for its utility in clinical management and diagnosis of intracranial hemorrhage (ICH), the use of neonatal cranial point‐of‐care ultrasound (POCUS) has not been standardized in neonatal intensive care units (NICUs) in the United States. The primary aim of this study was to evaluate the feasibility of training NICU providers to perform cranial POCUS by tracking the quality of image acquisition following training.
Methods
Observational single‐center cohort study of cranial POCUS images obtained by trained neonatal practitioners (attendings, fellows, and advanced practice providers) using a protocol developed by a radiologist and neonatologist. Exams were performed on infants born ≤1250 g and/or ≤30 weeks gestation within the first 3 days after birth. A survey to assess attitudes regarding cranial POCUS was given before each of three training sessions. Demographic and clinical data collection were portrayed with descriptive statistics. Metrics of image quality were assessed by a radiologist and sonographer independently. Analysis of trends in quality of POCUS images over time was performed using a multinomial Cochran‐Armitage test.
Results
Eighty‐two cranial POCUS scans were performed over a 2‐year period. Infant median age at exam was 14 hours (IQR 7–22 hours). Metrics of image quality depicted quarterly demonstrated a significant improvement in depth ( P = .01), gain ( P = .048), and quality of anatomy images captured ( P < .001) over time. Providers perceived increased utility and safety of cranial POCUS over time.
Conclusion
Cranial POCUS image acquisition improved significantly following care team training, which may enable providers to diagnose ICH at the bedside.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatrics, Division of Neonatology, University of Washington/Seattle Children's Hospital, Seattle, Washington, USA.
- Center on Human Development and Disability, University of Washington, Seattle, Washington, USA.
- Department of Radiology, University of Washington, Seattle, Washington, USA.
ORCID-Profile: Sarah E Kolnik, Mihai Puia-Dumitrescu
Zitieren
APA
Kolnik, S. E., Sahota, A., Wood, T. R., German, K., Puia-Dumitrescu, M., Mietzsch, U., Dighe, M., & Law, J. B. (2024). Cranial Point‐of‐Care Ultrasound for Neonatal Providers. Journal of Ultrasound in Medicine, 43(6), 1089-1097. https://doi.org/10.1002/jum.16437
Vancouver
Kolnik SE, Sahota A, Wood TR, German K, Puia-Dumitrescu M, Mietzsch U, et al. Cranial Point‐of‐Care Ultrasound for Neonatal Providers. Journal of Ultrasound in Medicine. 2024;43(6):1089-1097. doi:10.1002/jum.16437
BibTeX
@article{Kolnik2024,
author = {Kolnik, Sarah E and Sahota, Annika and Wood, Thomas R and German, Kendell and Puia-Dumitrescu, Mihai and Mietzsch, Ulrike and Dighe, Manjiri and Law, Janessa B},
title = {Cranial Point‐of‐Care Ultrasound for Neonatal Providers},
journal = {Journal of Ultrasound in Medicine},
year = {2024},
volume = {43},
number = {6},
pages = {1089--1097},
doi = {10.1002/jum.16437}
}
EUVIMED