Quantitative Evaluation of the Lumbar Multifidus Muscle by Shear Wave Dispersion in Healthy Adults: A Preliminary Study
Journal of Ultrasound in Medicine · 2024
DOI: 10.1002/jum.16416 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Ultrasound in Medicine, 2024. Verfasst von Qiuxiang Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, First Affiliated Hospital of Anhui Medical University, Hefei, China. Hauptthemen laut MEDLINE: Paraspinal Muscles, Elasticity Imaging Techniques. Die Arbeit nennt 35 Literaturangaben.
Abstract (Originalsprache)
Objectives
To investigate the application value of shear wave dispersion (SWD) in healthy adults with the lumbar multifidus muscle (LMM), to determine the range of normal reference values, and to analyze the influences of factors on the parameter.
Methods
Ninety‐five healthy volunteers participated in the study, from whom 2‐dimensional, shear wave elastography (SWE), and SWD images of the bilateral LMM were acquired in three positions (prone, standing, and anterior flexion). Subcutaneous fat thickness (SFH), SWE velocity, and SWD slope were measured accordingly for analyses.
Results
The mean SWD slope of the bilateral LMM in the prone position was as follows: left: 14.8 ± 3.1 (m/second)/kHz (female) and 13.0 ± 2.5 (m/second)/kHz (male); right: 14.8 ± 3.7 (m/second)/kHz (female) and 14.2 ± 3.4 (m/second)/kHz (male). In the prone position, there was a weak negative correlation between the bilateral LMM SWD slope of activity level 2 and level 1 ( β = −1.5 (2 versus 1, left), −1.9 (2 versus 1, right), all P < .05), and between the left SWD slope of activity level 3 and level 1 ( β = −2.3 [3 versus 1, left], P < .05). The correlation between SWE velocity and SWD slope value changed with the position: there was a weak positive correlation in the prone position ( r = 0.3 [left], 0.37 [right], both P < .05), and a moderate positive correlation in the standing and anterior flexed positions ( r = 0.49–0.74, both P < .001). SFH was moderately negatively correlated with bilateral SWD slope values in the anterior flexion (left: r = −0.4, P = .01; right: r = −0.7, P < .01).
Conclusions
SWD imaging can be used as an adjunct tool to aid in the assessment of viscosity in LMM. Further, activity level, and position are influencing factors that should be considered in clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound, First Affiliated Hospital of Anhui Medical University, Hefei, China.
- Department of Ultrasound, First Affiliated Hospital of Shenzhen University Health Science Center, Shenzhen Second People's Hospital, Shenzhen, China.
- Department of Ultrasound, Yijishan Hospital of Wannan Medical College, Wuhu, China.
ORCID-Profile: Qiuxiang Chen, Chaoxue Zhang
Zitieren
APA
Chen, Q., Li, Z., Deng, M., Peng, J., Zhu, X., & Zhang, C. (2024). Quantitative Evaluation of the Lumbar Multifidus Muscle by Shear Wave Dispersion in Healthy Adults: A Preliminary Study. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.16416
Vancouver
Chen Q, Li Z, Deng M, Peng J, Zhu X, Zhang C. Quantitative Evaluation of the Lumbar Multifidus Muscle by Shear Wave Dispersion in Healthy Adults: A Preliminary Study. Journal of Ultrasound in Medicine. 2024. doi:10.1002/jum.16416
BibTeX
@article{Chen2024,
author = {Chen, Qiuxiang and Li, Zhenzhou and Deng, Meifang and Peng, Jiayu and Zhu, Xiangming and Zhang, Chaoxue},
title = {Quantitative Evaluation of the Lumbar Multifidus Muscle by Shear Wave Dispersion in Healthy Adults: A Preliminary Study},
journal = {Journal of Ultrasound in Medicine},
year = {2024},
doi = {10.1002/jum.16416}
}
EUVIMED