Resonance, Velocity, Dispersion, and Attenuation of Ultrasound‐Induced Shear Wave Propagation in Blood Clot In Vitro Models
Journal of Ultrasound in Medicine · 2024
DOI: 10.1002/jum.16387 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Ultrasound in Medicine, 2024. Verfasst von Guillaume Bosio und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomedical Engineering, University of Montreal, Montreal, Quebec, Canada. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Thrombosis. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 77 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
Objective
Improve the characterization of mechanical properties of blood clots. Parameters derived from shear wave (SW) velocity and SW amplitude spectra were determined for gel phantoms and in vitro blood clots.
Methods
Homogeneous phantoms and phantoms with gel or blood clot inclusions of different diameters and mechanical properties were analyzed. SW amplitude spectra were used to observe resonant peaks. Parameters derived from those resonant peaks were related to mimicked blood clot properties. Three regions of interest were tested to analyze where resonances occurred the most. For blood experiments, 20 samples from different pigs were analyzed over time during a 110‐minute coagulation period using the Young modulus, SW frequency dispersion, and SW attenuation.
Results
The mechanical resonance was manifested by an increase in the number of SW spectral peaks as the inclusion diameter was reduced ( P < .001). In blood clot inclusions, the Young modulus increased over time during coagulation ( P < .001). Descriptive spectral parameters (frequency peak, bandwidth, and distance between resonant peaks) were linearly correlated with clot elasticity values ( P < .001) with R 2 = .77 for the frequency peak, .60 for the bandwidth, and .48 for the distance between peaks. The SW dispersion and SW attenuation reflecting the viscous behavior of blood clots decreased over time ( P < .001), mainly in the early stage of coagulation (first minutes).
Conclusion
The confined soft inclusion configuration favored SW mechanical resonances potentially challenging the computation of spectral‐based parameters, such as the SW attenuation. The impact of resonances can be reduced by properly selecting the region of interest for data analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Biomedical Engineering, University of Montreal, Montreal, Quebec, Canada.
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada.
- Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montreal, Montreal, Quebec, Canada.
ORCID-Profile: Guy Cloutier
Förderung
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Bosio, G., Destrempes, F., Yazdani, L., Roy Cardinal, M. H., & Cloutier, G. (2024). Resonance, Velocity, Dispersion, and Attenuation of Ultrasound‐Induced Shear Wave Propagation in Blood Clot In Vitro Models. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.16387
Vancouver
Bosio G, Destrempes F, Yazdani L, Roy Cardinal MH, Cloutier G. Resonance, Velocity, Dispersion, and Attenuation of Ultrasound‐Induced Shear Wave Propagation in Blood Clot In Vitro Models. Journal of Ultrasound in Medicine. 2024. doi:10.1002/jum.16387
BibTeX
@article{Bosio2024,
author = {Bosio, Guillaume and Destrempes, François and Yazdani, Ladan and Roy Cardinal, Marie-Hélène and Cloutier, Guy},
title = {Resonance, Velocity, Dispersion, and Attenuation of Ultrasound‐Induced Shear Wave Propagation in Blood Clot In Vitro Models},
journal = {Journal of Ultrasound in Medicine},
year = {2024},
doi = {10.1002/jum.16387}
}
EUVIMED