Intra‐ and Interobserver Reliability of Shear Wave Elastography in Breast Cancer Diagnosis
Journal of Ultrasound in Medicine · 2024
DOI: 10.1002/jum.16344 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Ultrasound in Medicine, 2024. Verfasst von Riku Togawa und 15 weiteren Autor:innen. Beteiligte Einrichtung: University Breast Unit, Department of Obstetrics and Gynecology, Heidelberg University Hospital, Heidelberg, Germany. Hauptthemen laut MEDLINE: Breast Neoplasms, Elasticity Imaging Techniques. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objectives
Shear wave elastography (SWE) is increasingly used in breast cancer diagnostics. However, large, prospective, multicenter data evaluating the reliability of SWE is missing. We evaluated the intra‐ and interobserver reliability of SWE in patients with breast lesions categorized as BIRADS 3 or 4.
Methods
We used data of 1288 women at 12 institutions in 7 countries with breast lesions categorized as BIRADS 3 to 4 who underwent conventional B‐mode ultrasound and SWE. 1243 (96.5%) women had three repetitive conventional B‐mode ultrasounds as well as SWE measurements performed by a board‐certified senior physician. 375 of 1288 (29.1%) women received an additional ultrasound examination with B‐mode and SWE by a second physician. Intraclass correlation coefficients (ICC) were calculated to examine intra‐ and interobserver reliability.
Results
ICC for intraobserver reliability showed an excellent correlation with ICC >0.9, while interobserver reliability was moderate with ICC of 0.7. There were no clinically significant differences in intraobserver reliability when SWE was performed in lesions categorized as BI‐RADS 3 or 4 as well as in histopathologically benign or malignant lesions.
Conclusion
Reliability of additional SWE was evaluated on a study cohort consisting of 1288 breast lesions categorized as BI‐RADS 3 and 4. SWE shows an excellent intraobserver reliability and a moderate interobserver reliability in the evaluation of solid breast masses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University Breast Unit, Department of Obstetrics and Gynecology, Heidelberg University Hospital, Heidelberg, Germany.
- Institute of Medical Biometry (IMBI), University of Heidelberg, Heidelberg, Germany.
- Breast Unit, Sankt Elisabeth Hospital, Heidelberg, Germany.
- Department of Radiology, University of Coimbra, Coimbra, Portugal.
- Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany.
- Department of Radiology, Sagara Hospital, Kagoshima, Japan.
ORCID-Profile: André Pfob
Zitieren
APA
Togawa, R., Pfob, A., Büsch, C., Fastner, S., Gomez, C., Goncalo, M., Hennigs, A., Killinger, K., Nees, J., Riedel, F., Schäfgen, B., Stieber, A., Tozaki, M., Heil, J., Barr, R., & Golatta, M. (2024). Intra‐ and Interobserver Reliability of Shear Wave Elastography in Breast Cancer Diagnosis. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.16344
Vancouver
Togawa R, Pfob A, Büsch C, Fastner S, Gomez C, Goncalo M, et al. Intra‐ and Interobserver Reliability of Shear Wave Elastography in Breast Cancer Diagnosis. Journal of Ultrasound in Medicine. 2024. doi:10.1002/jum.16344
BibTeX
@article{Togawa2024,
author = {Togawa, Riku and Pfob, André and Büsch, Christopher and Fastner, Sarah and Gomez, Christina and Goncalo, Manuela and Hennigs, André and Killinger, Kristina and Nees, Juliane and Riedel, Fabian and Schäfgen, Benedikt and Stieber, Anne and Tozaki, Mitsuhiro and Heil, Jörg and Barr, Richard and Golatta, Michael},
title = {Intra‐ and Interobserver Reliability of Shear Wave Elastography in Breast Cancer Diagnosis},
journal = {Journal of Ultrasound in Medicine},
year = {2024},
doi = {10.1002/jum.16344}
}
EUVIMED