Fachartikel in der Zeitschrift Journal of Ultrasound in Medicine, 2023. Verfasst von Bin-Bin Jin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Ultrasound, The First Affiliated Hospital of Guangxi Medical University, Nanning, China. Hauptthemen laut MEDLINE: Contrast Media, Infertility, Female. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To analyze the risk factors of sulfur hexafluoride microbubble contrast agent intravasation during hysterosalpingo‐contrast sonography (HyCoSy), and to explore a simple prediction model by the obvious clinical history.

Methods

This was a retrospective study included 299 infertility women who had undergone HyCoSy examination from July 1, 2018 to June 31, 2019. The factors were recorded, including age, endometrial thickness, balloon length, infertility type, history of intrauterine surgery, history of pelvic surgery, and tubal patency. The method of multivariate logistic regression analysis was adopted to analyze the risk factors affecting the contrast agent intravasation, and the receiver operating characteristic curves were plotted to test their efficacy.

Results

Secondary infertility, a history of intrauterine surgery, thin endometrial thickness, and tubal obstruction were all risk factors of the occurrence of intravasation ( P < .05). And the area under the receiver operating characteristic curves of the multifactor‐combined prediction model of the intravasation was significantly larger than that of single‐factor.

Conclusions

Sonographers and gynecologists should be familiar with the risk factors of intravasation and select the appropriate timing of HyCoSy toward reducing the occurrence of intravasation and other complications after thoroughly explaining and communicating with the patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaInfertility, FemaleHumansFemaleSulfur HexafluorideFallopian TubesHysterosalpingographyRetrospective StudiesMicrobubblesFallopian Tube Patency TestsUltrasonographyRisk Factors

Stichwörter der Autor:innen

contrast agentfallopian tube patencyhysterosalpingo-contrast sonographyinfertilityintravasationultrasonography

Substanzen

Contrast MediaSulfur Hexafluoride

Autor:innen und Institutionen

  • Department of Medical Ultrasound, The First Affiliated Hospital of Guangxi Medical University, Nanning, China.

ORCID-Profile: Bin-Bin Jin, Shang-Yong Zhu

Zitieren

APA

Jin, B. B., Ma, Y., Zhao, X. H., Teng, Y. L., & Zhu, S. Y. (2023). Risk Factors of Contrast Agent Intravasation With Sulfur Hexafluoride Microbubble During Hysterosalpingo‐Contrast Sonography. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.16179

Vancouver

Jin BB, Ma Y, Zhao XH, Teng YL, Zhu SY. Risk Factors of Contrast Agent Intravasation With Sulfur Hexafluoride Microbubble During Hysterosalpingo‐Contrast Sonography. Journal of Ultrasound in Medicine. 2023. doi:10.1002/jum.16179

BibTeX
@article{Jin2023,
  author = {Jin, Bin-Bin and Ma, Yan and Zhao, Xiu-Hua and Teng, Yi-Ling and Zhu, Shang-Yong},
  title = {Risk Factors of Contrast Agent Intravasation With Sulfur Hexafluoride Microbubble During Hysterosalpingo‐Contrast Sonography},
  journal = {Journal of Ultrasound in Medicine},
  year = {2023},
  doi = {10.1002/jum.16179}
}
Kostenlos starten →