EUVIMEDEUVIMED entdecken
Crossref

Modelling Retention Behavior Over Broad Ranges of Organic Modifier Concentrations in Reversed‐Phase Liquid Chromatography Columns

Kristof Vynckier, Leon Niezen, Bram Huygens, Judith Mollen, Deirdre Cabooter, Gert Desmet

Journal of Separation Science · 2026-10 · 49 (10)

DOI: 10.1002/jssc.70548 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Separation Science, online erschienen am 08.10.2026. Verfasst von Kristof Vynckier und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Vrije Universiteit Brussel, Brussel, Belgium. Die Arbeit nennt 48 Literaturangaben. Gefördert von: Methusalem Funding from the Flemish Government.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The present study aimed to investigate how complex an analytical retention time model needs to be to closely represent the strong curvature in the relation between the logarithm of the retention factor and the fraction of organic modifier that is often observed when exploring broad ranges of . This is, for example, the case during automated method development. It was found that, when covering wide ‐ranges, 3‐parameter models are essential to capture the curvature of vs. relations, with the Neue–Kuss (NK) and hybrid‐log (HYL) models outperforming the standard quadratic model. However, moving to 4‐parameter models still yielded a statistically significant improvement, as confirmed by the RMSE values (from 0.051 to 0.016 median) and the Akaike Information Criterion (AIC)‐values (with ΔAIC > 10), especially for data sets containing compounds that exhibited a retention minimum. Among these, two newly proposed models performed slightly better than the standard cubic model in both global fitting accuracy and high‐ extrapolation accuracy. Even so, relatively large performance variance across all methods implied that important exceptions to these general trends exist.

Schlagwörter

Stichwörter der Autor:innen

Akaike information criteriondata fittinghydrophilic interaction liquid chromatographymethod developmentretention modelretention time

Autor:innen und Institutionen

  • Department of Chemical Engineering, Vrije Universiteit Brussel, Brussel, Belgium.
  • Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, KU Leuven, Leuven, Belgium.

Förderung

  • Methusalem Funding from the Flemish Government

Zitieren

APA

Vynckier, K., Niezen, L., Huygens, B., Mollen, J., Cabooter, D., & Desmet, G. (2026). Modelling Retention Behavior Over Broad Ranges of Organic Modifier Concentrations in Reversed‐Phase Liquid Chromatography Columns. Journal of Separation Science, 49(10). https://doi.org/10.1002/jssc.70548

Vancouver

Vynckier K, Niezen L, Huygens B, Mollen J, Cabooter D, Desmet G. Modelling Retention Behavior Over Broad Ranges of Organic Modifier Concentrations in Reversed‐Phase Liquid Chromatography Columns. Journal of Separation Science. 2026;49(10). doi:10.1002/jssc.70548

BibTeX
@article{Vynckier2026,
  author = {Vynckier, Kristof and Niezen, Leon and Huygens, Bram and Mollen, Judith and Cabooter, Deirdre and Desmet, Gert},
  title = {Modelling Retention Behavior Over Broad Ranges of Organic Modifier Concentrations in Reversed‐Phase Liquid Chromatography Columns},
  journal = {Journal of Separation Science},
  year = {2026},
  volume = {49},
  number = {10},
  doi = {10.1002/jssc.70548}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche