Hydrophobic Menthol‐Based Deep Eutectic Solvent for Ultrasound‐Assisted Dispersive Liquid‒Liquid Microextraction of Amide Herbicides in Food and Environmental Samples Before Determination by HPLC

Menghong Xie, Guxi Huang, Hao Wang, Jiazhen Wei, Junliang Lin, Yipeng Huang, Guihua Ruan

Journal of Separation Science · 2026-05 · 49 (5)

DOI: 10.1002/jssc.70433 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Separation Science, online erschienen am 04.05.2026. Verfasst von Menghong Xie und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Bioengineering, Guilin University of Technology, Guangxi, China. Hauptthemen laut MEDLINE: Herbicides, Menthol, Liquid Phase Microextraction, Amides. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Natural Science Foundation from Guangxi Zhuang Autonomous Region, Guangxi Zhuang Autonomous Region Science and Technology Major Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Toxic amide herbicide residues pose significant risks to food safety and environmental health. In this study, an ultrasound‐assisted dispersive liquid‒liquid extraction method utilizing a hydrophobic menthol‐based deep eutectic solvent (DES) was developed for the efficient separation and determination of four amide herbicides in complex matrices, including vegetables, soil, and water. DES composed of decanoic acid (hydrogen bond acceptor) and menthol (hydrogen bond donor) at a molar ratio of 2:3 demonstrated superior extraction performance compared to those using lauric or oleic acid as a hydrogen bond acceptor. The extraction was equilibrated within 2 min under neutral pH conditions. Molecular docking simulations revealed that the N─H groups in the amide moieties served as the primary active sites for hydrogen bonding interactions with the DES. By integrating this green extraction technique with high‐performance liquid chromatography, a robust analytical method was established, exhibiting excellent linearity ( R 2 > 0.9991) over a wide range (1–200 ng mL −1 ), with low limits of detection (0.3–0.5 ng mL −1 ) and high precision (intraday RSDs ≤ 3.6%, inter‐day RSDs ≤ 8.2%). The method achieved high recoveries (89.8%–116%) across various samples. Greenness assessments using the GAREEprep and Analytical Ecological Scale showed scores of 0.57 and 85, respectively, underscoring the sustainability of the method. This study presents a rapid, sensitive, and sustainable alternative for monitoring amide herbicide residues, contributing to food safety and environmental protection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HerbicidesMentholLiquid Phase MicroextractionAmidesDeep Eutectic SolventsFood ContaminationChromatography, High Pressure LiquidHydrophobic and Hydrophilic InteractionsMolecular Docking SimulationUltrasonic Waves

Stichwörter der Autor:innen

amide herbicidesdeep eutectic solventsdispersive liquid‒liquid extractiongreen analytical chemistrymolecular docking

Substanzen

HerbicidesMentholAmidesDeep Eutectic Solvents

Autor:innen und Institutionen

  • College of Chemistry and Bioengineering, Guilin University of Technology, Guangxi, China.

Förderung

  • Natural Science Foundation from Guangxi Zhuang Autonomous Region
  • Guangxi Zhuang Autonomous Region Science and Technology Major Project

Zitieren

APA

Xie, M., Huang, G., Wang, H., Wei, J., Lin, J., Huang, Y., & Ruan, G. (2026). Hydrophobic Menthol‐Based Deep Eutectic Solvent for Ultrasound‐Assisted Dispersive Liquid‒Liquid Microextraction of Amide Herbicides in Food and Environmental Samples Before Determination by HPLC. Journal of Separation Science, 49(5). https://doi.org/10.1002/jssc.70433

Vancouver

Xie M, Huang G, Wang H, Wei J, Lin J, Huang Y, et al. Hydrophobic Menthol‐Based Deep Eutectic Solvent for Ultrasound‐Assisted Dispersive Liquid‒Liquid Microextraction of Amide Herbicides in Food and Environmental Samples Before Determination by HPLC. Journal of Separation Science. 2026;49(5). doi:10.1002/jssc.70433

BibTeX
@article{Xie2026,
  author = {Xie, Menghong and Huang, Guxi and Wang, Hao and Wei, Jiazhen and Lin, Junliang and Huang, Yipeng and Ruan, Guihua},
  title = {Hydrophobic Menthol‐Based Deep Eutectic Solvent for Ultrasound‐Assisted Dispersive Liquid‒Liquid Microextraction of Amide Herbicides in Food and Environmental Samples Before Determination by HPLC},
  journal = {Journal of Separation Science},
  year = {2026},
  volume = {49},
  number = {5},
  doi = {10.1002/jssc.70433}
}
Kostenlos starten →