EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Simultaneous Detection and Quantification of Organic Acids and Furans in Lignocellulosic Biomass Hydrolysate Through High‐Performance Liquid Chromatography With Diode Array Detector

Patrizia Casella, Raffaele Loffredo, Maria Antonietta Rao, Federico Liuzzi, Isabella De Bari, Antonio Molino

Journal of Separation Science · 2025

DOI: 10.1002/jssc.70216 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Separation Science, 2025. Verfasst von Patrizia Casella und 5 weiteren Autor:innen. Beteiligte Einrichtung: Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Department of Sustainability, Division Sustainable Agri-Fo…. Hauptthemen laut MEDLINE: Lignin, Biomass, Furans. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Lignocellulosic biomass is gaining attention as low‐cost renewable resources for sugars for fermentation and as a source of energy. Pretreatments and fermentation of these biomasses can generate organic acids and furans. Many liquid chromatography protocols have been developed for the analysis of these compounds. Organic acids are typically detected and quantified using diode array detector, while furans can be analyzed by using refractive index or ultraviolet detectors. In this work, the identification of succinic, lactic, formic, and acetic acids and two furans (5‐hydroxymethylfurfural and furfural) was performed by ultra‐high‐performance liquid chromatography coupled with diode array detector and ion chromatography columns. Different chromatographic conditions were tested by varying the column temperature and the flow rate of sulfuric acid 5 mM. Calibration curves, peak resolution, limit of detection, and limit of quantification were calculated using analytical standards at known concentrations for each compound. The accuracy was evaluated by the recovery of the compounds in wheat straw hydrolysate. For succinic acid, the best condition was at a flow rate of 0.6 mL/min and a column temperature of 60°C while formic and lactic acids and furans were better recovered at 1.0 mL/min and 60°C.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LigninBiomassFuransChromatography, High Pressure LiquidHydrolysisFuraldehyde

Stichwörter der Autor:innen

5‐hydroxymethylfurfuralfurfuralsuccinic acidwheat straw

Substanzen

LigninlignocelluloseFuransFuraldehyde

Autor:innen und Institutionen

  • Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Department of Sustainability, Division Sustainable Agri-Food Systems, Laboratory Regenerative Circular Bioeconomy (ENEA-SSPT-AGR…
  • Department of Agricultural Sciences, University of Naples Fedrico II, Portici, Italy.
  • Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Department of Energy Technologies and Renewable Sources, Division Bioenergy, Biorefinery and Green Chemistry, Laboratory Techniq…

Zitieren

APA

Casella, P., Loffredo, R., Rao, M. A., Liuzzi, F., De Bari, I., & Molino, A. (2025). Simultaneous Detection and Quantification of Organic Acids and Furans in Lignocellulosic Biomass Hydrolysate Through High‐Performance Liquid Chromatography With Diode Array Detector. Journal of Separation Science. https://doi.org/10.1002/jssc.70216

Vancouver

Casella P, Loffredo R, Rao MA, Liuzzi F, De Bari I, Molino A. Simultaneous Detection and Quantification of Organic Acids and Furans in Lignocellulosic Biomass Hydrolysate Through High‐Performance Liquid Chromatography With Diode Array Detector. Journal of Separation Science. 2025. doi:10.1002/jssc.70216

BibTeX
@article{Casella2025,
  author = {Casella, Patrizia and Loffredo, Raffaele and Rao, Maria Antonietta and Liuzzi, Federico and De Bari, Isabella and Molino, Antonio},
  title = {Simultaneous Detection and Quantification of Organic Acids and Furans in Lignocellulosic Biomass Hydrolysate Through High‐Performance Liquid Chromatography With Diode Array Detector},
  journal = {Journal of Separation Science},
  year = {2025},
  doi = {10.1002/jssc.70216}
}
Kostenlos starten →