A Disposable Pipette Extraction‐UHPLC‐MS/MS Method Based on Removal of Phospholipids to Determine Anandamide, 2‐Arachidonoylglycerol, Cannabidiol, and Δ 9 ‐Tetrahydrocannabidiol in Plasma Samples
Journal of Separation Science · 2025
DOI: 10.1002/jssc.70068 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Separation Science, 2025. Verfasst von Igor Gustavo Carvalho Oliveira und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Philosophy, Sciences and Letters at Ribeirão Preto, University of São Paulo, São Paulo, Ribeirão Preto-SP, Brazil. Hauptthemen laut MEDLINE: Endocannabinoids, Arachidonic Acids, Polyunsaturated Alkamides, Glycerides. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 62 Literaturangaben. Gefördert von: São Paulo Research Foundation (FAPESP), Instituto Nacional de Ciência e Tecnologia Translational em Medicina (INCT-TM), Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.
Abstract (Originalsprache)
Cannabidiol (CBD) and Δ 9 ‐tetrahydrocannabinol (THC), the main components of Cannabis sativa plants, can interact with specific cell receptors known as cannabinoid receptors (CBs). The endogenous compounds anandamide (AEA) and 2‐arachidonoylglycerol (2‐AG) are CB agonists, and, alongside enzymes, they constitute the endocannabinoid system (ECS) and take part in neuromodulation. Several LC‐MS/MS methods have been developed to quantify these compounds in biological matrixes, but a fast and simple method that can determine these analytes in plasma samples simultaneously is not available. Here, we propose a disposable pipette extraction technique containing a zirconia‐based sorbent (DPX(Zr)) combined with UHPLC‐MS/MS analysis to determine CBD, THC, AEA, and 2‐AG in plasma samples, simultaneously. The method combines simple protein precipitation (PPT) with a one‐step DPX procedure to remove phospholipids, one of the most common endogenous interferents in biological samples. Optimization of the combined PPT‐DPX sample preparation method reduced the matrix effect and improved the sensitivity of the analytical method. The validated DPX(Zr)‐UHPLC‐MS/MS method reported LLOQs of 0.1 ng mL −1 for AEA and 2‐AG and 1 ng mL −1 for CBD and THC. The method demonstrated intra‐ and interassay accuracy and precision of less than 20% for the LLOQ, and less than 15% for the other calibration points. Additionally, no carryover or significant matrix effect was observed. We applied this method to determine AEA, 2‐AG, and CBD in plasma samples obtained from obsessive‐compulsive disorder patients treated with CBD.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Faculty of Philosophy, Sciences and Letters at Ribeirão Preto, University of São Paulo, São Paulo, Ribeirão Preto-SP, Brazil.
- Department of Neuroscience and Behavior, Ribeirão Preto Medical School, University of São Paulo, São Paulo, Ribeirão Preto-SP, Brazil.
ORCID-Profile: Maria Eugênia Costa Queiroz
Förderung
- São Paulo Research Foundation (FAPESP)
- Instituto Nacional de Ciência e Tecnologia Translational em Medicina (INCT-TM)
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Zitieren
APA
Oliveira, I. G. C., de Souza, I. D., de Crippa, J. A. S., & Queiroz, M. E. C. (2025). A Disposable Pipette Extraction‐UHPLC‐MS/MS Method Based on Removal of Phospholipids to Determine Anandamide, 2‐Arachidonoylglycerol, Cannabidiol, and Δ 9 ‐Tetrahydrocannabidiol in Plasma Samples. Journal of Separation Science. https://doi.org/10.1002/jssc.70068
Vancouver
Oliveira IGC, de Souza ID, de Crippa JAS, Queiroz MEC. A Disposable Pipette Extraction‐UHPLC‐MS/MS Method Based on Removal of Phospholipids to Determine Anandamide, 2‐Arachidonoylglycerol, Cannabidiol, and Δ 9 ‐Tetrahydrocannabidiol in Plasma Samples. Journal of Separation Science. 2025. doi:10.1002/jssc.70068
BibTeX
@article{Oliveira2025,
author = {Oliveira, Igor Gustavo Carvalho and de Souza, Israel Donizeti and de Crippa, José Alexandre de Souza and Queiroz, Maria Eugênia Costa},
title = {A Disposable Pipette Extraction‐UHPLC‐MS/MS Method Based on Removal of Phospholipids to Determine Anandamide, 2‐Arachidonoylglycerol, Cannabidiol, and Δ 9 ‐Tetrahydrocannabidiol in Plasma Samples},
journal = {Journal of Separation Science},
year = {2025},
doi = {10.1002/jssc.70068}
}
EUVIMED