EUVIMEDEUVIMED entdecken
Crossref

A robust method for simultaneous determination of eight B vitamins in human serum by liquid chromatography tandem mass spectrometry

Yu-Mei Huo iD, Shang-Qing Zhang, Gao-Ping Wu, Hong-Bo Shan, Chao Pan

Journal of Separation Science · 2024

DOI: 10.1002/jssc.202300576 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Separation Science, 2024. Verfasst von Yu-Mei Huo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Hangzhou Adicon Clinical Laboratories Co., Ltd, Hangzhou, P. R. China. Hauptthemen laut MEDLINE: Vitamin B Complex. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Adicon Clinical Laboratory and Department of Chemistry, Northeastern University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The level of vitamin B group in human serum is an important index of human health. Among B vitamins, cyanocobalamin in serum is unstable and its content is extremely low. Rapid and simultaneous detection of multiple B vitamins including cyanocobalamin is a challenge. Herein, we have developed a rapid and stable method that can realize the determination of thiamine, riboflavin, nicotinamide, pantothenic acid, pyridoxic acid, biotin, 5‐methyltetrahydrofolate, and cyanocobalamin simultaneously in 6 min. The method was established based on protein precipitation with methanol and then chromatographic separation was achieved using Waters acquity ultra‐high‐performance liquid chromatography high strength silica T3 column, which was stable and sensitive especially for cyanocobalamin. Limit of quantification, precision, trueness, and matrix effect were validated according to the European Medicines Agency and United States Food and Drug guidelines and Clinical and Laboratory Standards Institute guidelines on bioanalytical method. The limit of quantification for thiamine, riboflavin, nicotinamide, pantothenic acid, pyridoxic acid, biotin, 5‐methyltetrahydrofolate, and cyanocobalamin was 0.4, 0.4, 0.8, 2.0, 0.4, 0.1, 0.4, and 0.04 ng/mL separately, respectively. Intra‐ and interday precisions were 1.1%–12.4% and 2.0%–13.5%, respectively. The relative errors were between 0.3% and 13.3%, and the matrix effects were between 2.6% and 10.4%.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vitamin B ComplexHumansPantothenic AcidBiotinTandem Mass SpectrometryPyridoxic AcidChromatography, LiquidThiamineRiboflavinNiacinamideVitamin B 12Chromatography, High Pressure LiquidVitamin AVitamin K

Stichwörter der Autor:innen

simultaneous determinationultra-high-performance liquid chromatographyvitamin B

Substanzen

Vitamin B ComplexPantothenic AcidBiotinPyridoxic AcidThiamineRiboflavinNiacinamideVitamin B 12Vitamin AVitamin K

Autor:innen und Institutionen

  • Hangzhou Adicon Clinical Laboratories Co., Ltd, Hangzhou, P. R. China.
  • Department of Chemistry, College of Sciences, Northeastern University, Shenyang, P. R. China.

ORCID-Profile: Yu-Mei Huo

Förderung

  • Adicon Clinical Laboratory and Department of Chemistry, Northeastern University

Zitieren

APA

Huo, Y. M., Zhang, S. Q., Wu, G. P., Shan, H. B., & Pan, C. (2024). A robust method for simultaneous determination of eight B vitamins in human serum by liquid chromatography tandem mass spectrometry. Journal of Separation Science. https://doi.org/10.1002/jssc.202300576

Vancouver

Huo YM, Zhang SQ, Wu GP, Shan HB, Pan C. A robust method for simultaneous determination of eight B vitamins in human serum by liquid chromatography tandem mass spectrometry. Journal of Separation Science. 2024. doi:10.1002/jssc.202300576

BibTeX
@article{Huo2024,
  author = {Huo, Yu-Mei and Zhang, Shang-Qing and Wu, Gao-Ping and Shan, Hong-Bo and Pan, Chao},
  title = {A robust method for simultaneous determination of eight B vitamins in human serum by liquid chromatography tandem mass spectrometry},
  journal = {Journal of Separation Science},
  year = {2024},
  doi = {10.1002/jssc.202300576}
}
Kostenlos starten →