EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Validation of a liquid chromatography‐tandem mass spectrometry method for simultaneous quantification of N , N ‐dimethylacetamide and N ‐monomethylacetamide in pediatric plasma

Sebastian P A Rosser iD, Andrew J McLachlan, Georg Hempel, Jason Chung, Peter J Shaw, Steven J Keogh, Christa E Nath

Journal of Separation Science · 2023

DOI: 10.1002/jssc.202201003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Separation Science, 2023. Verfasst von Sebastian P A Rosser und 6 weiteren Autor:innen. Beteiligte Einrichtung: The Children's Hospital at Westmead Clinical School, University of Sydney, Sydney, Australia. Hauptthemen laut MEDLINE: Busulfan, Tandem Mass Spectrometry. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

N,N –dimethylacetamide is an excipient used in intravenous busulfan formulations, a drug used in hematopoietic stem cell transplantation conditioning. The aim of this study was to develop and validate a liquid chromatography‐tandem mass spectrometry method for simultaneous quantification of N , N ‐dimethylacetamide, and its metabolite N ‐monomethylacetamide in plasma from children receiving busulfan. A 4 μl aliquot of patient plasma was extracted using 196 μl 50% methanol solution and quantified against calibrators prepared in the extraction solvent given negligible matrix effects across three concentrations. 9 [H 2 ]‐ N,N ‐dimethylacetamide was used as an internal standard. Separation of N,N ‐dimethylacetamide and N ‐monomethylacetamide was achieved using a Kinetex EVO C18 stationary phase (100 mm × 2.1 mm × 2.6 μm) running an isocratic mobile phase of 30% methanol containing 0.1% formic acid at a flow of 0.2 ml/min over 3.0 min. The injection volume was 1 μl. Calibration curves for N,N ‐dimethylacetamide and N ‐monomethylacetamide were linear up to 1200 and 200 μg/L, respectively, with a lower limit of quantification 1 μg/L for both analytes. Calibrator accuracy and precision were within ± 10% of the test parameters across four concentration levels. Analytes were stable over 14 days at three different storage conditions. This method was successfully applied to measure N,N ‐dimethylacetamide and N ‐monomethylacetamide concentrations in a total of 1265 plasma samples from 77 children.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BusulfanTandem Mass SpectrometryChildHumansMethanolChromatography, LiquidChromatography, High Pressure LiquidAcetamides

Stichwörter der Autor:innen

N,N-dimethylacetamideN-monomethylacetamideliquid chromatography-tandem mass spectrometrymethod validationpharmacokinetics

Substanzen

BusulfanMethanoldimethylacetamideAcetamides

Autor:innen und Institutionen

  • The Children's Hospital at Westmead Clinical School, University of Sydney, Sydney, Australia.
  • Department of Biochemistry, The Children's Hospital at Westmead, Sydney, Australia.
  • Cancer Centre for Children, The Children's Hospital at Westmead, Sydney, Australia.
  • Sydney Pharmacy School, Faculty of Medicine and Health, University of Sydney, Sydney, Australia.
  • Institute for Pharmaceutical and Medicinal Chemistry and Clinical Pharmacy, University of Münster, Sydney, Germany.

ORCID-Profile: Sebastian P A Rosser

Zitieren

APA

Rosser, S. P. A., McLachlan, A. J., Hempel, G., Chung, J., Shaw, P. J., Keogh, S. J., & Nath, C. E. (2023). Validation of a liquid chromatography‐tandem mass spectrometry method for simultaneous quantification of N , N ‐dimethylacetamide and N ‐monomethylacetamide in pediatric plasma. Journal of Separation Science. https://doi.org/10.1002/jssc.202201003

Vancouver

Rosser SPA, McLachlan AJ, Hempel G, Chung J, Shaw PJ, Keogh SJ, et al. Validation of a liquid chromatography‐tandem mass spectrometry method for simultaneous quantification of N , N ‐dimethylacetamide and N ‐monomethylacetamide in pediatric plasma. Journal of Separation Science. 2023. doi:10.1002/jssc.202201003

BibTeX
@article{Rosser2023,
  author = {Rosser, Sebastian P A and McLachlan, Andrew J and Hempel, Georg and Chung, Jason and Shaw, Peter J and Keogh, Steven J and Nath, Christa E},
  title = {Validation of a liquid chromatography‐tandem mass spectrometry method for simultaneous quantification of N , N ‐dimethylacetamide and N ‐monomethylacetamide in pediatric plasma},
  journal = {Journal of Separation Science},
  year = {2023},
  doi = {10.1002/jssc.202201003}
}
Kostenlos starten →