Reliability of Ultrasonography to Assess Spinal Compression During Heavy Load Carriage
JOR SPINE · 2026-03 · 9 (1)
DOI: 10.1002/jsp2.70137 ↗Kurz gefasst
Fachartikel in der Zeitschrift JOR SPINE, online erschienen am 10.02.2026. Verfasst von Sherrilyn Walters und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Health and Medical Sciences University of Southern Queensland Ipswich Queensland Australia. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Government.
Abstract (Originalsprache)
Background
Back pain and spinal injury are leading contributors to premature retirement, particularly in physically demanding occupations. Direct and practical methods of spinal assessment are needed to evaluate interventions aimed at reducing spinal loading and injury risk. Ultrasonography has been reliably used to estimate spinal compression via intervertebral disc height, but its reliability for measuring inter‐transverse process distances under load has not been established.
Methods
Eleven healthy adults underwent ultrasonographic measurement of inter‐transverse process distances at each lumbar level (L1–L5), and the total lumbar distance under four loading conditions: (1) immediately on standing while unloaded, (2) after 15 min of unloaded standing, (3) after 15 min of standing loaded with a 25 kg weighted vest, and (4) after 30 min of loaded standing. These procedures were repeated after 1–7 days. Inter‐rater, within‐visit, and between‐visit reliability were assessed using intraclass correlation coefficients (ICCs) and coefficients of variation (CV). Bland–Altman plots were used to assess agreement. A one‐way analysis of variance was used to determine the effects of each loading condition on inter‐transverse process distances.
Results
Inter‐rater, within‐visit, and between‐visit reliability was good to excellent with ICCs between 0.81 and 0.99 and CVs between 5.24% and 13.0% for all measurements. Inter‐transverse process distances were reduced at L2/3 ( p = 0.007), L3/4 ( p = 0.006), and across the total lumbar distance ( p = 0.02) following 15 and 30 min of loaded standing.
Conclusion
Ultrasonography is a reliable, low‐cost method for quantifying changes in lumbar spine geometry during loaded standing. This technique may have value in occupational and clinical settings for assessing spinal compression in response to mechanical load.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Health and Medical Sciences University of Southern Queensland Ipswich Queensland Australia.
- Martial Arts Research and Testing Laboratory Toowoomba Queensland Australia.
- School of Medicine and Dentistry Griffith University Gold Coast Queensland Australia.
- Centre for Health Research, Institute for Resilient Regions University of Southern Queensland Ipswich Queensland Australia.
- Faculty of Health University of Canberra Research Institute for Sport and Exercise, University of Canberra Bruce Australian Capital Territory Australia.
ORCID-Profile: Sherrilyn Walters, Celeste E Coltman
Förderung
- Australian Government
Zitieren
APA
Walters, S., Hoffman, B., Coltman, C. E., Walters, L., Iqbal, M., & Mills, D. E. (2026). Reliability of Ultrasonography to Assess Spinal Compression During Heavy Load Carriage. JOR SPINE, 9(1). https://doi.org/10.1002/jsp2.70137
Vancouver
Walters S, Hoffman B, Coltman CE, Walters L, Iqbal M, Mills DE. Reliability of Ultrasonography to Assess Spinal Compression During Heavy Load Carriage. JOR SPINE. 2026;9(1). doi:10.1002/jsp2.70137
BibTeX
@article{Walters2026,
author = {Walters, Sherrilyn and Hoffman, Ben and Coltman, Celeste E and Walters, Lester and Iqbal, Muneeb and Mills, Dean E},
title = {Reliability of Ultrasonography to Assess Spinal Compression During Heavy Load Carriage},
journal = {JOR SPINE},
year = {2026},
volume = {9},
number = {1},
doi = {10.1002/jsp2.70137}
}
EUVIMED