EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Application and Validation of Semiautomatic Quantification of Immunohistochemically Stained Sections for Low Cellular Tissue Such as Intervertebral Disc Using QuPath

Andrea Nüesch iD, Maria Paola Ferri iD, Christine L Le Maitre iD

JOR SPINE · 2025-03 · 8 (1)

DOI: 10.1002/jsp2.70054 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JOR SPINE, online erschienen am 06.03.2025. Verfasst von Andrea Nüesch und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Clinical Medicine, School of Medicine and Population Health University of Sheffield Sheffield UK. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Immunohistochemistry (IHC) is a widely used method for localizing and semi‐quantifying proteins in tissue samples. Traditional IHC analysis often relies on manually counting 200 cells within a designated area, a time‐intensive and subjective process that can compromise reproducibility and accuracy. Advances in digital scanning and bioimage analysis tools, such as the open‐source software QuPath, enable semi‐automated cell counting, reducing subjectivity and increasing efficiency.

Aims

This project developed a QuPath‐based script and detailed guide for semi‐automatic cell counting, specifically for tissues with low cellularity, such as intervertebral discs and cartilage. Methods and Results The methodology was validated by demonstrating no significant differences between the manual counting and the semi‐automatic quantification ( p = 0.783, p = 0.386) while showing a strong correlation between methods for both collagen type II staining ( r = 0.9602, p < 0.0001) and N‐cadherin staining ( r = 0.9044, p = 0.0001). Furthermore, a strong correlation (intraclass correlation coefficient (ICC) single raters = 0.853) between 3 individual raters with varying academic ranks and experiences in IHC analysis was shown using the semi‐automatic quantification method. Discusssion The approach ensures high reproducibility and accuracy, with reduced variability between raters and laboratories. This semi‐automated method is particularly suited for tissues with a high extracellular matrix to cell ratio and low cellularity. By minimizing subjectivity and evaluation time, it provides a robust alternative to manual counting, making it ideal for applications where reproducibility and standardization are critical. While the methodology was effective in low‐cellularity tissues, its application in other tissue types warrants further exploration.

Conclusions

These findings underscore the potential of QuPath to streamline IHC analysis and enhance inter‐laboratory comparability.

Schlagwörter

Stichwörter der Autor:innen

IVDimage analysisimmunohistochemistryquantificationsemi‐automated

Autor:innen und Institutionen

  • Division of Clinical Medicine, School of Medicine and Population Health University of Sheffield Sheffield UK.
  • Barcelona Supercomputing Center Barcelona Spain.
  • Universitat de Barcelona Barcelona Spain.

ORCID-Profile: Andrea Nüesch, Maria Paola Ferri, Christine L Le Maitre

Zitieren

APA

Nüesch, A., Ferri, M. P., & Le Maitre, C. L. (2025). Application and Validation of Semiautomatic Quantification of Immunohistochemically Stained Sections for Low Cellular Tissue Such as Intervertebral Disc Using QuPath. JOR SPINE, 8(1). https://doi.org/10.1002/jsp2.70054

Vancouver

Nüesch A, Ferri MP, Le Maitre CL. Application and Validation of Semiautomatic Quantification of Immunohistochemically Stained Sections for Low Cellular Tissue Such as Intervertebral Disc Using QuPath. JOR SPINE. 2025;8(1). doi:10.1002/jsp2.70054

BibTeX
@article{Nesch2025,
  author = {Nüesch, Andrea and Ferri, Maria Paola and Le Maitre, Christine L},
  title = {Application and Validation of Semiautomatic Quantification of Immunohistochemically Stained Sections for Low Cellular Tissue Such as Intervertebral Disc Using QuPath},
  journal = {JOR SPINE},
  year = {2025},
  volume = {8},
  number = {1},
  doi = {10.1002/jsp2.70054}
}
Kostenlos starten →