Lipid profiling of electrosurgical vapors for real‐time assistance of soft tissue sarcoma resection
Journal of Surgical Oncology · 2024-03 · 129 (3) · 499-508
DOI: 10.1002/jso.27502 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Surgical Oncology, online erschienen am 05.12.2023. Verfasst von Pierre-Maxence Vaysse und 7 weiteren Autor:innen. Beteiligte Einrichtung: Maastricht MultiModal Molecular Imaging institute (M4i), University of Maastricht, Maastricht, The Netherlands. Hauptthemen laut MEDLINE: Sarcoma, Soft Tissue Neoplasms. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Dutch Province of Limburg, Maastricht Universitair Medisch Centrum.
Abstract (Originalsprache)
Background
Soft tissue sarcomas (STS) constitute a heterogeneous group of rare tumor entities. Treatment relies on challenging patient‐tailored surgical resection. Real‐time intraoperative lipid profiling of electrosurgical vapors by rapid evaporative ionization mass spectrometry (REIMS) may aid in achieving successful surgical R0 resection (i.e., microscopically negative‐tumor margin resection). Here, we evaluate the ex vivo accuracy of REIMS to discriminate and identify various STS from normal surrounding tissue.
Methods
Twenty‐seven patients undergoing surgery for STS at Maastricht University Medical Center+ were included in the study. Samples of resected STS specimens were collected and analyzed ex vivo using REIMS. Electrosurgical cauterization of tumor and surrounding was generated successively in both cut and coagulation modes. Resected specimens were subsequently processed for gold standard histopathological review. Multivariate statistical analysis (principal component analysis‐linear discriminant analysis) and leave‐one patient‐out cross‐validation were employed to compare the classifications predicted by REIMS lipid profiles to the pathology classifications. Electrosurgical vapors produced during sarcoma resection were analyzed in vivo using REIMS.
Results
In total, 1200 histopathologically‐validated ex vivo REIMS lipid profiles were generated from 27 patients. Ex vivo REIMS lipid profiles classified STS and normal tissues with 95.5% accuracy. STS, adipose and muscle tissues were classified with 98.3% accuracy. Well‐differentiated liposarcomas and adipose tissues could not be discriminated based on their respective lipid profiles. Distinction of leiomyosarcomas from other STS could be achieved with 96.6% accuracy. In vivo REIMS analyses generated intense mass spectrometric signals.
Conclusion
Lipid profiling by REIMS is able to discriminate and identify STS with high accuracy and therefore constitutes a potential asset to improve surgical resection of STS in the future.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Maastricht MultiModal Molecular Imaging institute (M4i), University of Maastricht, Maastricht, The Netherlands.
- Department of Surgery, Maastricht University Medical Center, Maastricht, The Netherlands.
- Department of Otorhinolaryngology, Head & Neck Surgery, Maastricht University Medical Center, Maastricht, The Netherlands.
- Department of Pathology, Maastricht University Medical Center, Maastricht, The Netherlands.
- GROW School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht, The Netherlands.
- Department of General, Visceral and Transplantation Surgery, RWTH University Hospital Aachen, Aachen, Germany.
Förderung
- Dutch Province of Limburg
- Maastricht Universitair Medisch Centrum
Zitieren
APA
Vaysse, P. M., van den Hout, M. F. C. M., Engelen, S. M. E., Keymeulen, K. B. M. I., Bemelmans, M. H. A., Heeren, R. M. A., Olde Damink, S. W. M., & Porta Siegel, T. (2024). Lipid profiling of electrosurgical vapors for real‐time assistance of soft tissue sarcoma resection. Journal of Surgical Oncology, 129(3), 499-508. https://doi.org/10.1002/jso.27502
Vancouver
Vaysse PM, van den Hout MFCM, Engelen SME, Keymeulen KBMI, Bemelmans MHA, Heeren RMA, et al. Lipid profiling of electrosurgical vapors for real‐time assistance of soft tissue sarcoma resection. Journal of Surgical Oncology. 2024;129(3):499-508. doi:10.1002/jso.27502
BibTeX
@article{Vaysse2024,
author = {Vaysse, Pierre-Maxence and van den Hout, Mari F C M and Engelen, Sanne M E and Keymeulen, Kristien B M I and Bemelmans, Marc H A and Heeren, Ron M A and Olde Damink, Steven W M and Porta Siegel, Tiffany},
title = {Lipid profiling of electrosurgical vapors for real‐time assistance of soft tissue sarcoma resection},
journal = {Journal of Surgical Oncology},
year = {2024},
volume = {129},
number = {3},
pages = {499--508},
doi = {10.1002/jso.27502}
}
EUVIMED