Studienprotokoll in der Zeitschrift Journal of Surgical Oncology, online erschienen am 04.01.2023. Verfasst von Merel A Spiekerman van Weezelenburg und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Zuyderland Medical Centre, Sittard-Geleen, The Netherlands. Hauptthemen laut MEDLINE: Sentinel Lymph Node, Breast Neoplasms. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 21 Literaturangaben.
Abstract (Originalsprache)
Background
Localisation techniques for nonpalpable breast cancer lesions and sentinel lymph node biopsy (SLNB) are associated with several drawbacks. A complete magnetic technique using magnetic seeds and superparamagnetic iron oxide tracer could be an interesting alternative. This study describes a clear protocol and the results of a combined magnetic approach.
Methods
From August 2021 to February 2022 40 patients undergoing breast conserving surgery with SLNB were eligible for inclusion. Localisation was performed under ultrasound or stereotactic guidance, 1 week before surgery. Subsequently, 1 ml of tracer was injected at least 4 cm away from the tumour. Technetium‐99m ( 99m Tc) was injected 1 day before surgery as control procedure. Outcomes were SLNB time, a number of nodes detected with magnetic tracer including comparison with 99m Tc, a success rate of malignant lesion detection and pathological margin assessment.
Results
In total, 40 procedures were performed on 39 patients. A median of one node was retrieved. Sentinel nodes were retrieved using MagTrace® with a 92.5% detection rate compared to 99m Tc. Wide local excision under magnetic guidance was successful in 35 cases.
Conclusions
This paper describes a combined magnetic approach for breast‐conserving surgery and SLNB. An adapted protocol is described and could be used for implementation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Surgery, Zuyderland Medical Centre, Sittard-Geleen, The Netherlands.
- Department of Radiology, Zuyderland Medical Centre, Sittard-Geleen, The Netherlands.
- Department of Clinical Engineering, Faculty of Science and Engineering, Maastricht University, Maastricht, The Netherlands.
Zitieren
APA
Spiekerman van Weezelenburg, M. A., van Haaren, E. R. M., Aldenhoven, L., Frotscher, C. N. A., Körver-Steeman, R., van Bastelaar, J., Bouwman, L. H., Vissers, Y. L. J., & Janssen, A. (2023). An adapted protocol for magnetic localisation of nonpalpable breast cancer lesions and sentinel lymph nodes using a magnetic seed and superparamagnetic iron oxide tracer. Journal of Surgical Oncology, 127(5), 776-781. https://doi.org/10.1002/jso.27197
Vancouver
Spiekerman van Weezelenburg MA, van Haaren ERM, Aldenhoven L, Frotscher CNA, Körver-Steeman R, van Bastelaar J, et al. An adapted protocol for magnetic localisation of nonpalpable breast cancer lesions and sentinel lymph nodes using a magnetic seed and superparamagnetic iron oxide tracer. Journal of Surgical Oncology. 2023;127(5):776-781. doi:10.1002/jso.27197
BibTeX
@article{SpiekermanvanWeezelenburg2023,
author = {Spiekerman van Weezelenburg, Merel A and van Haaren, Elisabeth R M and Aldenhoven, Loeki and Frotscher, Caroline N A and Körver-Steeman, Rachelle and van Bastelaar, James and Bouwman, Lee H and Vissers, Yvonne L J and Janssen, Alfred},
title = {An adapted protocol for magnetic localisation of nonpalpable breast cancer lesions and sentinel lymph nodes using a magnetic seed and superparamagnetic iron oxide tracer},
journal = {Journal of Surgical Oncology},
year = {2023},
volume = {127},
number = {5},
pages = {776--781},
doi = {10.1002/jso.27197}
}
EUVIMED