EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

BCARS Simulated Phantom Dataset for Evaluation of Processing Pipelines

Jessica Z. Dixon, Eric G. Baker, Charles H. Camp, Sidharth Laxminarayan, Abigail Bonde, Marcus T. Cicerone

Journal of Raman Spectroscopy · 2026-03 · 57 (3) · 530-543

DOI: 10.1002/jrs.70079 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Raman Spectroscopy, online erschienen am 27.11.2025. Verfasst von Jessica Z. Dixon und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. Department of Energy.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Broadband coherent anti‐Stokes Raman scattering (BCARS) microscopy is a powerful label‐free biological imaging technique, but the raw signal requires careful processing. The vibrationally resonant (Raman) fingerprint signal is usually small compared with instrumental noise sources and the nonresonant background (NRB) inherent in the BCARS signal. Fortunately, the NRB exhibits a systematic phase relationship with the coherent Raman response, acting as a heterodyne amplifier for the weak fingerprint signal. Due to this heterodyne effect, the Raman response can be recovered quantitatively and invariantly across different instruments, provided the NRB shape is known. Even with heterodyne amplification, the amplitudes of fingerprint signal components are often comparable to system noise. Singular value decomposition (SVD), which utilizes spatial information, is often employed for additional noise filtering. Consequently, finding optimal processing parameters to properly distinguish the NRB and Raman responses and suppress noise in the complex BCARS signal requires a reference system that realistically represents the spectral and spatial properties of BCARS signals obtained from biological samples. We present a digital tissue phantom that meets these criteria as a tool for testing candidate signal processing pipelines. The digital phantom is generated with simulated hyperspectral Raman images having system‐specific noise and background characteristics. We analyze phantom datasets with differing background and signal‐to‐noise conditions to evaluate their impact on the performance of multiple signal processing pipelines. Specifically, we investigate the application of a Butterworth filter‐based routine to directly estimate the NRB from the BCARS signal. Additionally, we evaluate a Lorentzian wavelet transform as an alternative to the Hilbert transform for extracting the Raman spectrum from the BCARS signal. While we demonstrate this phantom for BCARS, it can be used for any spectroscopic Raman imaging approach.

Förderung

  • U.S. Department of Energy

Zitieren

APA

Dixon, J. Z., Baker, E. G., Camp, C. H., Laxminarayan, S., Bonde, A., & Cicerone, M. T. (2026). BCARS Simulated Phantom Dataset for Evaluation of Processing Pipelines. Journal of Raman Spectroscopy, 57(3), 530-543. https://doi.org/10.1002/jrs.70079

Vancouver

Dixon JZ, Baker EG, Camp CH, Laxminarayan S, Bonde A, Cicerone MT. BCARS Simulated Phantom Dataset for Evaluation of Processing Pipelines. Journal of Raman Spectroscopy. 2026;57(3):530-543. doi:10.1002/jrs.70079

BibTeX
@article{Dixon2026,
  author = {Dixon, Jessica Z. and Baker, Eric G. and Camp, Charles H. and Laxminarayan, Sidharth and Bonde, Abigail and Cicerone, Marcus T.},
  title = {BCARS Simulated Phantom Dataset for Evaluation of Processing Pipelines},
  journal = {Journal of Raman Spectroscopy},
  year = {2026},
  volume = {57},
  number = {3},
  pages = {530--543},
  doi = {10.1002/jrs.70079}
}
Kostenlos starten →