EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Comparison of colonoscopic versus fluoroscopic colonic manometry catheter placement in children

Anna E Leone, Julia M J van der Zande iD, Shruthi Srinivas, Maria Knaus, Richard J Wood, Mark J Hogan, Marc A Benninga, Raul E Sanchez, Neetu Bali Puri, Karla Vaz, Desale Yacob, Carlo Di Lorenzo und 1 weitere

Journal of Pediatric Gastroenterology and Nutrition · 2025

DOI: 10.1002/jpn3.12429 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Pediatric Gastroenterology and Nutrition, 2025. Verfasst von Anna E Leone und 12 weiteren Autor:innen. Beteiligte Einrichtung: Division of Gastroenterology, Hepatology, and Nutrition, Department of Pediatrics, Nationwide Children's Hospital, Columbus, Ohio, USA. Hauptthemen laut MEDLINE: Manometry, Colonoscopy, Catheterization, Colon. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Cultuurfonds with support from the Jadefonds, Amsterdam University Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Colonic manometry catheter placement can be performed by colonoscopy or fluoroscopy. Our objective was to compare outcomes of colonoscopic to fluoroscopic catheter placement in children based on the extent of colon study and the likelihood of catheter displacement.

Methods

Colonic manometry studies performed between May 2015 and May 2022 were reviewed. All studies with catheter placement per rectum were included. Data on patient demographics, medical and surgical history, and information on catheter placement (type of catheter, placement technique, position, and displacement) were recorded.

Results

We reviewed 555 studies and included 482 studies performed on 453 children (51% female, median age 10 years, interquartile range: 7–14 years). The catheter was placed during colonoscopy in 274 studies and using fluoroscopy in 208 studies. Children with colonoscopic placement were significantly older (median age 11 vs. 8 years, p < 0.001), more commonly male (55% vs . 41%, p = 0.003), and more commonly had functional constipation (85% vs. 69%, p < 0.001). Children with fluoroscopic placement more often had pediatric intestinal pseudo‐obstruction (10% vs . 1%, p < 0.001), a diverting ostomy (21% vs. 7%, p < 0.001), and a cecostomy (10% vs. 4%, p = 0.023). A successful catheter placement (reaching ascending colon) was significantly more common using colonoscopy (49% vs . 23%, p < 0.001). There were no differences in frequency or extent of catheter displacement between colonoscopic and fluoroscopic placement.

Conclusions

Colonoscopic placement was superior to fluoroscopic placement in terms of the extent of the colon studied with no differences in frequency of catheter displacement. Colonoscopic placement should be the preferred method in most children with refractory constipation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ManometryColonoscopyCatheterizationColonHumansChildFluoroscopyMaleFemaleAdolescentConstipationCatheters

Stichwörter der Autor:innen

colonoscopyfluoroscopymotilitypediatrics

Autor:innen und Institutionen

  • Division of Gastroenterology, Hepatology, and Nutrition, Department of Pediatrics, Nationwide Children's Hospital, Columbus, Ohio, USA.
  • The Ohio State University College of Medicine, Columbus, Ohio, USA.
  • Department of Pediatric Gastroenterology and Nutrition, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.
  • Department of Colorectal and Pelvic Reconstructive Surgery, Nationwide Children's Hospital, Columbus, Ohio, USA.
  • Section of Vascular and Interventional Radiology, Department of Radiology, Nationwide Children's Hospital, Columbus, Ohio, USA.

ORCID-Profile: Julia M J van der Zande

Förderung

  • Cultuurfonds with support from the Jadefonds
  • Amsterdam University Fund

Zitieren

APA

Leone, A. E., van der Zande, J. M. J., Srinivas, S., Knaus, M., Wood, R. J., Hogan, M. J., Benninga, M. A., Sanchez, R. E., Puri, N. B., Vaz, K., Yacob, D., Di Lorenzo, C., & Lu, P. L. (2025). Comparison of colonoscopic versus fluoroscopic colonic manometry catheter placement in children. Journal of Pediatric Gastroenterology and Nutrition. https://doi.org/10.1002/jpn3.12429

Vancouver

Leone AE, van der Zande JMJ, Srinivas S, Knaus M, Wood RJ, Hogan MJ, et al. Comparison of colonoscopic versus fluoroscopic colonic manometry catheter placement in children. Journal of Pediatric Gastroenterology and Nutrition. 2025. doi:10.1002/jpn3.12429

BibTeX
@article{Leone2025,
  author = {Leone, Anna E and van der Zande, Julia M J and Srinivas, Shruthi and Knaus, Maria and Wood, Richard J and Hogan, Mark J and Benninga, Marc A and Sanchez, Raul E and Puri, Neetu Bali and Vaz, Karla and Yacob, Desale and Di Lorenzo, Carlo and Lu, Peter L},
  title = {Comparison of colonoscopic versus fluoroscopic colonic manometry catheter placement in children},
  journal = {Journal of Pediatric Gastroenterology and Nutrition},
  year = {2025},
  doi = {10.1002/jpn3.12429}
}
Kostenlos starten →