Diagnostic accuracy of transmucosal probe visualization for peri‐implant mucosal phenotype assessment: A cross‐sectional study

Emilio Couso-Queiruga, Manrique Fonseca, Diogo Moreira Rodrigues, Gustavo Avila-Ortiz, Vivianne Chappuis, Clemens Raabe

Journal of Periodontology · 2026-07 · 97 (7) · 1407-1417

DOI: 10.1002/jper.70062 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Periodontology, online erschienen am 26.01.2026. Verfasst von Emilio Couso-Queiruga und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral Surgery and Stomatology, University of Bern School of Dental Medicine, Bern, Switzerland. Hauptthemen laut MEDLINE: Mouth Mucosa, Dental Implants, Single-Tooth. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study evaluated the diagnostic accuracy of visual assessment of mucosal transparency using a standard periodontal probe (VAT) to differentiate between thin and thick peri‐implant mucosal phenotypes, compared to horizontal transmucosal probing (HTP). A secondary objective was to assess facial mucosal thickness (FMT) threshold values for peri‐implant mucosa phenotype classification.

Methods

Adult subjects with at least one non‐molar single implant‐supported prosthesis (ISP) were screened. To evaluate VAT, a standard periodontal probe was inserted through the peri‐implant sulcus on the midfacial aspect. FMT was measured via HTP using an endodontic spreader.

Results

A total of 247 subjects and 281 ISPs constituted the study population. Setting a 2 mm threshold, 66.2% of sites were classified as thick and 33.8% as thin. Compared to HTP, VAT demonstrated a sensitivity (SE) of 12.6%, a specificity (SP) of 96.2%, a positive predictive value (PPV) of 63%, and a negative predictive value (NPV) of 66%. At the 1.5 mm threshold, 86.1% of sites were thick and 13.9% thin, with 25.6% SE, 96.3% SP, 53% PPV, and 89% NPV. At the 1 mm threshold, 92.2% of sites were thick and 7.8% thin, with 41% SE, 96% SP, 47% PPV, and 95% NPV. Receiver operating characteristic analysis revealed the best‐fitting balance for PPV (58%) and NPV (91%) at an FMT of 1.25 mm.

Conclusions

Regardless of the FMT threshold applied, VAT demonstrated limited diagnostic accuracy, in particular for thin phenotypes, proving unreliable for the dichotomic characterization of thin and thick peri‐implant mucosal phenotypes. This study was approved by the ethical committee for clinical studies in the canton of Bern, Switzerland (KEK‐BE‐No. 2023‐01962).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mouth MucosaDental Implants, Single-ToothHumansFemalePhenotypeCross-Sectional StudiesMaleMiddle AgedAdultSensitivity and SpecificityDental Prosthesis, Implant-SupportedAgedPredictive Value of Tests

Stichwörter der Autor:innen

dental implantsestheticsoutcome assessmentoutcome measuresphenotype

Autor:innen und Institutionen

  • Department of Oral Surgery and Stomatology, University of Bern School of Dental Medicine, Bern, Switzerland.
  • Department of Reconstructive Dentistry and Gerodontology, University of Bern School of Dental Medicine, Bern, Switzerland.
  • Department of Periodontology, National Institute of Dental Sciences, Niterói, Rio de Janeiro, Brazil.
  • Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan, USA.

Zitieren

APA

Couso-Queiruga, E., Fonseca, M., Rodrigues, D. M., Avila-Ortiz, G., Chappuis, V., & Raabe, C. (2026). Diagnostic accuracy of transmucosal probe visualization for peri‐implant mucosal phenotype assessment: A cross‐sectional study. Journal of Periodontology, 97(7), 1407-1417. https://doi.org/10.1002/jper.70062

Vancouver

Couso-Queiruga E, Fonseca M, Rodrigues DM, Avila-Ortiz G, Chappuis V, Raabe C. Diagnostic accuracy of transmucosal probe visualization for peri‐implant mucosal phenotype assessment: A cross‐sectional study. Journal of Periodontology. 2026;97(7):1407-1417. doi:10.1002/jper.70062

BibTeX
@article{CousoQueiruga2026,
  author = {Couso-Queiruga, Emilio and Fonseca, Manrique and Rodrigues, Diogo Moreira and Avila-Ortiz, Gustavo and Chappuis, Vivianne and Raabe, Clemens},